Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Interest
Topics
Details

Details

  • Name

    Francisco Sousa Fernandes
  • Role

    Researcher
  • Since

    27th April 2020
013
Publications

2025

Location of grid forming converters when dealing with multi-class stability problems

Authors
Fernandes, F; Lopes, JP; Moreira, C;

Publication
IET Generation, Transmission & Distribution

Abstract

2024

Data Augmented Rule-based Expert System to Control a Hybrid Storage System

Authors
Bessa, RJ; Lobo, F; Fernandes, F; Silva, B;

Publication
2024 IEEE 22ND MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, MELECON 2024

Abstract
Hybrid storage systems that combine high energy density and high power density technologies can enhance the flexibility and stability of microgrids and local energy communities under high renewable energy shares. This work introduces a novel approach integrating rule-based (RB) methods with evolutionary strategies (ES)-based reinforcement learning. Unlike conventional RB methods, this approach involves encoding rules in a domain-specific language and leveraging ES to evolve the symbolic model via data-driven interactions between the control agent and the environment. The results of a case study with Liion and redox flow batteries show that the method effectively extracted rules that minimize the energy exchanged between the community and the grid.

2024

COMBINING BATTERIES AND SYNCHRONOUS CONDENSERS: THE CASE STUDY OF MADEIRA ISLAND

Authors
Fernandes, F; Lopes, JP; Moreira, C;

Publication
IET Conference Proceedings

Abstract
This paper investigates the stability of a converter-dominated islanded power system when the island’s battery energy storage converters are operated in different control modes (Grid Forming and Grid Following) and combined with different volumes of synchronous compensation. The study is conducted in a realistic simulation model of the future Madeira island, where no thermal generation is present, and the share of converter-based Renewable Energy Sources is large (75 to 80 % of instantaneous penetration). The impact of the different combinations of synchronous condensers and BESS converter control modes on the system stability is evaluated using a stability index-based approach that accounts for multiple operation scenarios. In this procedure, the system’s dynamic response to the reference disturbances (short-circuits in the Transmission and Distribution Network) is obtained via RMS dynamic simulation and is then analyzed to extract two stability indices (Nadir and Rocof). Such indices are computed for the synchronous generator speed and the grid electrical frequency (measured in different points using a PLL) and are later used as the basis for discussion and conclusion drawing. © Energynautics GmbH.

2023

The role of hydrogen electrolysers in frequency related ancillary services: A case study in the Iberian Peninsula up to 2040

Authors
Ribeiro, FJ; Lopes, JAP; Fernandes, FS; Soares, FJ; Madureira, AG;

Publication
SUSTAINABLE ENERGY GRIDS & NETWORKS

Abstract
This paper investigates the contribution of hydrogen electrolysers (HEs) for frequency related Ancillary Services (AS), namely Frequency Containment Reserve (FCR), Synthetic Inertia (SI) , Fast Frequency Response (FFR) in future operation scenarios in the Iberian Peninsula (IP) considering low system iner-tia. The proposed framework for analysis consists of a dynamic model developed in MATLAB/Simulink. Simulations show that an instantaneous inverter based resource (IBR) trip induced by a grid fault may lead to the occurrence of values of Rate of Change of Frequency (RoCoF) close to undesirable thresholds if the FCR is provided solely by the conventional generators. The obtained results illustrate that HEs can outperform conventional generators on the provision of FCR. Furthermore, the FCR is unable to unlock the full potential of fast responding HEs. This suggests the advantage of providing additional AS such as SI or FFR in critical periods. Simulations also show that the benefit of additional AS can be limited in specific conditions, especially depending on the evolution of HEs' ramping capabilities, but are still a relevant complement to other solutions designed to deal with low inertia in power systems such as synchronous compensators.& COPY; 2023 Elsevier Ltd. All rights reserved.

2023

Multi-Class Stability Analysis of the Grid-Forming Placement Problem

Authors
Fernandes, F; Lopes, JP; Moreira, C;

Publication
2023 IEEE BELGRADE POWERTECH

Abstract
This paper evidences the ability of a VSM-based grid-forming to mitigate stability problems of different classes, raising a special concern towards the importance of its location in systems with large converter-interfaced renewable energy systems. Within this context, a multi-class stability assessment, that pillars on the simulation of different nature disturbances and in the subsequent evaluation of a 4 index set, was performed. Such analysis was carried out on a modified version of the IEEE39 Test System, using DigSILENT Power Factory as the simulation engine.