Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Publications

Publications by CAP

2022

A Plasmonic Biosensor Based on Light-Diffusing Fibers Functionalized with Molecularly Imprinted Nanoparticles for Ultralow Sensing of Proteins

Authors
Arcadio, F; Seggio, M; Del Prete, D; Buonanno, G; Mendes, J; Coelho, LCC; Jorge, PAS; Zeni, L; Bossi, AM; Cennamo, N;

Publication
NANOMATERIALS

Abstract
Plasmonic bio/chemical sensing based on optical fibers combined with molecularly imprinted nanoparticles (nanoMIPs), which are polymeric receptors prepared by a template-assisted synthesis, has been demonstrated as a powerful method to attain ultra-low detection limits, particularly when exploiting soft nanoMIPs, which are known to deform upon analyte binding. This work presents the development of a surface plasmon resonance (SPR) sensor in silica light-diffusing fibers (LDFs) functionalized with a specific nanoMIP receptor, entailed for the recognition of the protein human serum transferrin (HTR). Despite their great versatility, to date only SPR-LFDs functionalized with antibodies have been reported. Here, the innovative combination of an SPR-LFD platform and nanoMIPs led to the development of a sensor with an ultra-low limit of detection (LOD), equal to about 4 fM, and selective for its target analyte HTR. It is worth noting that the SPR-LDF-nanoMIP sensor was mounted within a specially designed 3D-printed holder yielding a measurement cell suitable for a rapid and reliable setup, and easy for the scaling up of the measurements. Moreover, the fabrication process to realize the SPR platform is minimal, requiring only a metal deposition step.

2022

Effects of Pulse Duration in Laser-induced Breakdown Spectroscopy

Authors
Ferreira, MFS; Silva, NA; Guimarães, D; Martins, RC; Jorge, PAS;

Publication
U.Porto Journal of Engineering

Abstract
Laser-induced breakdown spectroscopy (LIBS) is a technique that leverages atomic emission towards element identification and quantification. While the potential of the technology is vast, it still struggles with obstacles such as the variability of the technique. In recent years, several methods have exploited modifications to the standard implementation to work around this problem, mostly focused on the laser side to increase the signal-to-noise ratio of the emission. In this paper, we explore the effect of pulse duration on the detected signal intensity using a tunable LIBS system that consists of a versatile fiber laser, capable of emitting square-shaped pulses with a duration ranging from 10 to 100 ns. Our results show that, by tuning the duration of the pulse, it is possible to increase the signal-to-noise ratio of relevant elemental emission lines, an effect that we relate with the computed plasma temperature and associated density for the ion species. Despite the limitations of the work due to the low-resolution and small range of the spectrometer used, the preliminary results pave an interesting path towards the design of controllable LIBS systems that can be tailored to increase the signal-to-noise ratio and thus be useful for the deployment of more sensitive instruments both for qualitative and quantitative purposes. © 2022, Universidade do Porto - Faculdade de Engenharia. All rights reserved.

2022

Towards robust calibration models for laser-induced breakdown spectroscopy using unsupervised clustered regression techniques

Authors
Silva N.A.; Capela D.; Ferreira M.; Gonçalves F.; Lima A.; Guimarães D.; Jorge P.A.S.;

Publication
Results in Optics

Abstract
One of the caveats of laser-induced breakdown spectroscopy technique is the performance for quantification purposes, in particular when the matrix of the sample is complex or the problem spans over a wide range of concentrations. These two questions are key issues for geology applications including ore grading in mining operations and typically lead to sub-optimal results. In this work, we present the implementation of a class of clustered regression calibration algorithms, that previously search the sample space looking for similar samples before employing a linear calibration model that is trained for that cluster. For a case study involving lithium quantification in three distinct exploration drills, the obtained results demonstrate that building local models can improve the performance of standard linear models in particular in the lower concentration region. Furthermore, we show that the models generalize well for unseen data of exploration drills on distinct rock veins, which can motivate not only further research on this class of methods but also technological applications for similar mining environments.

2022

Differential Refractometric Biosensor for Reliable Human IgG Detection: Proof of Concept

Authors
Mendes, JP; Coelho, LCC; Jorge, PAS; Pereira, CM;

Publication
BIOSENSORS-BASEL

Abstract
A new sensing platform based on long-period fiber gratings (LPFGs) for direct, fast, and selective detection of human immunoglobulin G (IgG; Mw = 150 KDa) was developed and characterized. The transducer's high selectivity is based on the specific interaction of a molecularly imprinted polymer (MIPs) design for IgG detection. The sensing scheme is based on differential refractometric measurements, including a correction system based on a non-imprinted polymer (NIP)-coated LPFG, allowing reliable and more sensitive measurements, improving the rejection of false positives in around 30%. The molecular imprinted binding sites were performed on the surface of a LPFG with a sensitivity of about 130 nm/RIU and a FOM of 16 RIU-1. The low-cost and easy to build device was tested in a working range from 1 to 100 nmol/L, revealing a limit of detection (LOD) and a sensitivity of 0.25 nmol/L (0.037 mu g/mL) and 0.057 nm.L/nmol, respectively. The sensor also successfully differentiates the target analyte from the other abundant elements that are present in the human blood plasma.

2022

Comprehensive comparison of linear and non-linear methodologies for lithium quantification in geological samples using LIBS

Authors
Ferreira, MFS; Capela, D; Silva, NA; Goncalves, F; Lima, A; Guimaraes, D; Jorge, PAS;

Publication
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY

Abstract
Laser-induced breakdown spectroscopy allows fast chemical analysis of light elements without significant sample preparation, turning it into a promising technique for on-site mining operations. Still, the performance for quantification purposes remains its major caveat, obstructing a broader application of the technique. In this work, we present an extensive comparison of the performances of distinct algorithms for quantification of Lithium in a mining prospection stage, using spectra acquired with both a commercial handheld device and a laboratory prototype. Covering both linear and non-linear methodologies, the results show that, when covering a wide range of concentrations typical on a mining operation, non-linear methodologies manage to achieve errors compatible with a semi-quantitative performance, offering performances better than those obtained with linear methods, which are more affected by saturation and matrix effects. The findings enclosed offer support for future applications in the field and may possibly be generalized for other elements of interest in similar mining environments.

2022

Optical biosensor for the detection of low concentrations of hydrogen peroxide in milk samples

Authors
Vasconcelos, H; Matias, A; Mendes, J; Arahjo, J; Dias, B; Jorge, PAS; Saraivaa, C; Coelho, LCC; de Almeida, JMMM;

Publication
OPTICAL SENSING AND DETECTION VII

Abstract
A strategy for the detection of H2O2 as a milk adulterant using a single shot membrane sensor, is presented. Direct quantitative evaluation of H2O2 in raw, skimmed, semi-skimmed and whole milk was carried out based on a chemiluminescence reaction with luminol. For H2O2 water solutions a linear response was attained from 0.0001% to 0.007 %w/w, with a limit of detection of 3x10(-5) %w/w. A coefficient of determination, R-2, greater than 0.97 was achieved, with a relative standard deviation (RSD) not exceeding 10%. In the analyzed milk samples, the lowest H2O2 concentration detected was 0.001% w/w for raw and for skim milk and 0.002%w/w for, semi-skimmed and whole milk. The presented method is original, sensitive, rapid, and cost-effective. Due to the achieved sensitivity the method has great potential to be used for H2O2 detection in diverse areas, such as environmental monitoring and food quality.

  • 10
  • 231