Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Publications

Publications by CAP

2019

Optical Fiber Humidity Sensor Based on Polyvinylidene Fluoride Fabry-Perot

Authors
Vaz, A; Barroca, N; Ribeiro, M; Pereira, A; Frazao, O;

Publication
IEEE PHOTONICS TECHNOLOGY LETTERS

Abstract
An optical fiber Fabry-Perot (FP) for relative humidity (RH) sensing is proposed. The FP cavity is fabricated by splicing a short length of hollow silica tube in a single mode fiber. The fiber is then coated with a polyvinylidene fluoride (PVDF) thin film to work as a mirror. The fabrication process of the FP interferometer with a dip coating process in a PVDF/dimethyl formamide solution is presented. The pattern fringes of the FP suffer a wavelength shift due to the change in the PVDF's refractive index with the ambient RH variation. A short overview of the cavity's formation and stability is presented. The RH response of the FPI cavity is tested. The sensor presented a sensitivity of 32.54 pm/%RH at constant temperature and -15.2 pm/degrees C for temperature variation.

2019

Microfiber Knot Resonators for Sensing Applications

Authors
Gomes, AD; Frazao, O;

Publication
OPTICS, PHOTONICS AND LASER TECHNOLOGY 2017

Abstract
Microfiber knot resonators are widely applied in many different fields of action, of which an important one is the optical sensing. Microfiber knot resonators can easily be used to sense the external medium. The large evanescent field of light increase the interaction of light with the surrounding medium, tuning the resonance conditions of the structure. In some cases, the ability of light to give several turns in the microfiber knot resonator allows for greater interaction with deposited materials, providing an enhancement in the detection capability. So far a wide variety of physical and chemical parameters have been possible to measure using microfiber knot resonators. However, new developments and improvements are still being done in this field. In this chapter, a review on sensing with microfiber knot resonators is presented, with particular emphasis on the application of these structures as temperature and refractive index sensors. A detailed analysis on the properties of these structures and different assembling configurations is presented. An important discussion regarding the sensor stability is presented, as well as alternatives to increase the device robustness. An overview on the recent developments in coated microfiber knot resonators is also addressed. In the end, other microfiber knot configurations are explored and discussed.

2019

A Self-Referencing Intensity-Based Fabry-Perot Cavity for Curvature Measurement

Authors
Novais, S; Silva, SO; Frazão, O;

Publication
IEEE Sensors Letters

Abstract
In this article, a self-referencing intensity-based fiber optic sensor relying on the principle of Fabry-Perot interference is proposed and demonstrated to measure curvature. The sensor is manufactured producing an air bubble cavity between two sections of multimode fiber. By detecting optical power variations at specific wavelengths, it was possible to measure curvature, enabling this sensor as a self-referencing system. For this setup, the achieved curvature sensitivity was 0.561 ± 0.014 dB/m-1, with a correlation factor up to 0.997, within the measurement range of 0.0-0.8 m-1. The proposed system has several features, including the self-referencing characteristic and its structure simplicity in terms of measuring procedure, making it a useful system. © 2017 IEEE.

2019

Fabry-Perot cavity for curvature measurement in a medical needle

Authors
Novais, S; Silva, SO; Frazao, O;

Publication
SEVENTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS (EWOFS 2019)

Abstract
A reflective fiber optic sensor based on a Fabry-Perot cavity made by splicing two sections of multimode fiber is demonstrated to measure the needle curvature. The sensing structure was incorporated into a medical needle and characterized for curvature and temperature measurements. The maximum sensitivity of -0.152dB/m(-1) was obtained to the curvature measurements, with a resolution of 0.089m(-1). When subjected to temperature, the sensing head presented a low temperature sensitivity, which resulted in a small cross-sensitivity.

2019

Multiplexing optical fiber Fabry-Perot interferometers based on air-microcavities

Authors
Perez Herrera, RA; Novais, S; Bravo, M; Leandro, D; Silva, SF; Frazao, O; Lopez Amo, M;

Publication
SEVENTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS (EWOFS 2019)

Abstract
In this work we demonstrate the multiplexing capability of new optical fiber Fabry-Perot interferometers based on air-microcavities using a commercial FBG interrogator. Three optimized air-microcavity interferometer sensors have been multiplexed in a single network and have been monitored using the commercial FBGs interrogator in combination with FFT calculations. Results show a sensitivity of 2.18 pi rad/m epsilon and a crosstalk-free operation.

2019

Fiber Microsphere Coupled in a Taper for a Large Curvature Range

Authors
Robalinho, P; Frazao, O;

Publication
FIBERS

Abstract
This work consists of using an optical fiber microsphere as a sensor for a wide range of curvature radii. The microsphere was manufactured in a standard fiber with an electric arc. In order to maximize system efficiency, the microsphere was spliced in the center of a taper. This work revealed that the variations of the wavelength where the maxima and minima of the spectrum are located varies linearly with the curvature of the system with a maximum sensitive of 580 +/- 20 (pm km). This is because the direction of the input beam in the microsphere depends on the system curvature, giving rise to interferometric variations within the microsphere.

  • 37
  • 231