Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Publications

Publications by Luís Carlos Coelho

2020

Optical fiber probes for trapping and backscattered signal analysis of sub-mm particles

Authors
Rodrigues, SM; Paiva, JS; Silva, FM; Coelho, L; Marques, PVS; Cunha, JPS; Jorge, PAS;

Publication
Optics InfoBase Conference Papers

Abstract
Optical tweezers based on metallic-coated tapered optical fibers with an aperture at the apex are fabricated and their sensing ability is tested. Preliminary results show robustness in differentiating between a trapped and no trapped state. © 2021 The Author(s).

2023

Tuning bimetallic Au@Ag nanorods Localized Surface Plasmon Resonance on side-polished optical fiber sensing configurations at near-infrared wavelengths

Authors
dos Santos, SS; Mendes, J; de Almeida, MMM; Pastoriza Santos, I; Coelho, CC;

Publication
Proceedings of SPIE - The International Society for Optical Engineering

Abstract
The increasing demand for precise chemical and biological sensing has led to the development of highly efficient plasmonic optical fiber sensors. Therefore, it is essential to optimize and match the operating wavelength region of both the optical fiber configuration and localized surface plasmon resonance of nanoparticles (NPs). This can be achieved by developing NPs that can reach resonance at near-infrared wavelengths, where refractive index sensitivity is enhanced, and silica optical fibers have lower losses. High aspect-ratio bimetallic Au@Ag nanorods and different side-polished fiber structures are tested using numerical simulations. The selected optical fiber configuration was based on a side-polished fiber with a 1 mm polished section. It is compared power losses and power at the NP interface for two configurations: a step-index single-mode fiber (SMF) with core/cladding diameters of 8.2/125 µm and a multimode graded-index fiber (GIF) with 62.5/125 µm at various polishing depths. The results showed that the best performance for both configurations was achieved at similar polishing depths, namely 59.5 and 55.2 µm for the SMF and GIF, respectively. The optical impact of retardation effects due to the proximity with the fiber structure were also observed, which caused a reduction in sensitivity from 1750 nm/RIU to 1500 nm/RIU and a red-shift of around 70 nm. © 2023 SPIE.

2023

TEC4SEA-Developing maritime technology for a sustainable blue economy

Authors
Monica, P; Cruz, N; Almeida, JM; Silva, A; Silva, E; Pinho, C; Almeida, C; Viegas, D; Pessoa, LM; Lima, AP; Martins, A; Zabel, F; Ferreira, BM; Dias, I; Campos, R; Araujo, J; Coelho, LC; Jorge, PS; Mendes, J;

Publication
OCEANS 2023 - LIMERICK

Abstract
One way to mitigate the high costs of doing science or business at sea is to create technological infrastructures possessing all the skills and resources needed for successful maritime operations, and make those capabilities and skills available to the external entities requiring them. By doing so, the individual economic and scientific agents can be spared the enormous effort of creating and maintaining their own, particular set of equivalent capabilities, thus drastically lowering their initial operating costs. In addition to cost savings, operating based on fully-fledged, shared infrastructures not only allows the use of more advanced scientific equipment and highly skilled personnel, but it also enables the business teams (be it industry or research) to focus on their goals, rather than on equipment, logistics, and support. This paper will describe the TEC4SEA infrastructure, created precisely to operate as described. This infrastructure has been under implementation in the last few years, and has now entered its operational phase. This paper will describe it, present its current portfolio of services, and discuss the most relevant assets and facilities that have been recently acquired, so that the research and industrial communities requiring the use of such assets can fully evaluate their adequacy for their own purposes and projects.

2023

Optical fiber flowmeter based on graphene oxide coated michelson interferometer

Authors
Monteiro, CS; Ferreira, M; Mendes, JP; Coelho, LCC; Silva, SO; Frazao, O;

Publication
SENSORS AND ACTUATORS A-PHYSICAL

Abstract
Measuring gas and liquid flow rate is paramount in various scientific and industrial applications. This work presents an optical fiber flowmeter based on a graphene oxide (GO) coated Michelson interferometer. The interferometer is fabricated using a long-period fiber grating (LPFG) followed by a GO-coated single-mode fiber (SMF). By radiating the GO coating, it experiences photothermic effect that induces local heating of the film. This results in a variation in the effective refractive index in the cladding modes, which induces a phase shift on the interferometer spectrum. When a gas flow is introduced near the coated fiber, the hot-wire region will experience a reduction in temperature proportional to the flow rate. The flowmeter exhibited a linear wavelength shift to the flow rate with an absolute sensitivity of 17.4 +/- 0.8 pm/(L.min-1) for gas flow rates between 2 and 8 L/ min. Furthermore, the dynamic response of the sensor was studied, attaining a maximum response time of 1.1 +/- 0.4 s

2024

Impact of gaseous interferents on palladium expansion for hydrogen optical sensing: A time stability study

Authors
Almeida, MAS; Almeida, JMMMD; Coelho, LCC;

Publication
OPTICS AND LASER TECHNOLOGY

Abstract
Continuous monitoring of hydrogen (H2) concentration is critical for safer use, which can be done using optical sensors. Palladium (Pd) is the most commonly used transducer material for this monitoring. This material absorbs H2 leading to an isotropic expansion. This process is reversible but is affected by the interaction with interferents, and the lifetime of Pd thin films is a recurring issue. Fiber Bragg Grating (FBG) sensors are used to follow the strain induced by H2 on Pd thin films. In this work, it is studied the stability of Pd-coated FBGs, protected with a thin Polytetrafluoroethylene (PTFE) layer, 10 years after their deposition to assess their viability to be used as H2 sensors for long periods of time. It was found that Pd coatings that were PTFE-protected after deposition had a longer lifetime than unprotected films, with the same sensitivities that they had immediately after their deposition, namely 23 and 10 pm/vol% for the sensors with 150 and 100 nm of Pd, respectively, and a saturation point around 2 kPa. Furthermore, the Pd expansion was analyzed in the presence of H2, nitrogen (N2), carbon dioxide (CO2), methane (CH4) and water vapor (H2O), finding that H2O is the main interferent. Finally, an exhaustive test for 90 h is also done to analyze the long-term stability of Pd films in dry and humid environments, with only the protected sensor maintaining the long-term response. As a result, this study emphasizes the importance of using protective polymeric layers in Pd films to achieve the five-year lifetime required for a real H2 monitoring application.

2024

Optical pH Sensor Based on a Long-Period Fiber Grating Coated with a Polymeric Layer-by-Layer Electrostatic Self-Assembled Nanofilm

Authors
Pereira, JM; Mendes, JP; Dias, B; de Almeida, JMMM; Coelho, LCC;

Publication
SENSORS

Abstract
An optical fiber pH sensor based on a long-period fiber grating (LPFG) is reported. Two oppositely charged polymers, polyethylenimine (PEI) and polyacrylic acid (PAA), were alternately deposited on the sensing structure through a layer-by-layer (LbL) electrostatic self-assembly technique. Since the polymers are pH sensitive, their refractive index (RI) varies when the pH of the solution changes due to swelling/deswelling phenomena. The fabricated multilayer coating retained a similar property, enabling its use in pH-sensing applications. The pH of the PAA dipping solution was tuned so that a coated LPFG achieved a pH sensitivity of (6.3 +/- 0.2) nm/pH in the 5.92-9.23 pH range. Only two bilayers of PEI/PAA were used as an overlay, which reduces the fabrication time and increases the reproducibility of the sensor, and its reversibility and repeatability were demonstrated by tracking the resonance band position throughout multiple cycles between different pH solutions. With simulation work and experimental results from a low-finesse Fabry-Perot (FP) cavity on a fiber tip, the coating properties were estimated. When saturated at low pH, it has a thickness of 200 nm and 1.53 +/- 0.01 RI, expanding up to 310 nm with a 1.35 +/- 0.01 RI at higher pH values, mostly due to the structural changes in the PAA.

  • 25
  • 26