2017
Authors
Silva, S; Frazao, O;
Publication
2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS)
Abstract
This work presents a multimode interference-based fiber sensor in a cavity ring-down system for sensing temperature-induced refractive index (RI) changes of water. The sensing head is based in multimodal interference (MMI) and it was placed inside the fiber loop cavity of the CRD system. A modulated laser source was used to send pulses down into the fiber loop cavity and an erbium-doped fiber amplifier (EDFA) was placed in the fiber ring to provide an observable signal with a reasonable decay time. The behavior of the sensing head to temperature was studied due to its intrinsic sensitivity to said parameter - a sensitivity of -1.6 10(-9) s/C was attained. This allowed eliminating the temperature component from RI measurement of water and a linear sensitivity of 580 mu s/RIU in the RI range of 1.324-1.331 was obtained.
2013
Authors
Andre, RM; Marques, MB; Mergo, P; Frazao, O;
Publication
Optics InfoBase Conference Papers
Abstract
Two interferometers were proposed with different types of twin core fiber. Both are characterized in temperature and the topology based on photonic crystal fiber presents higher sensitivity. © OSA 2013.
2013
Authors
Rodriguez Cobo, L; Marques, AT; Lopez Higuera, JM; Santos, JL; Frazao, O;
Publication
Proceedings of SPIE - The International Society for Optical Engineering
Abstract
Several easy-to-manufacture designs based on a pair of Fiber Bragg Gratings structure embedded in Carbon Fiber Reinforced Plastic (CFRP) have been explored. These smart composites can be used for strain and temperature discrimination. A Finite Elements Analysis and Matlab software were used to study the mechanical responses and its optical behaviors. The results exhibited different sensitivity and using a matrix method it is possible to compensate the thermal drift in a real application keeping a simple manufacture process. © 2013 SPIE.
2015
Authors
Perez Herrera, RA; Andre, RM; Silva, SF; Becker, M; Schuster, K; Kobelke, J; Lopez Amo, M; Santos, JL; Frazao, O;
Publication
MEASUREMENT
Abstract
In this work, two all-fiber loop mirrors using a clover microstructured fiber for the simultaneous measurement of temperature and strain are presented. The sensing heads are formed by a short piece of clover microstructured fiber with 35 mm and 89 mm length respectively. The geometry of the fiber allowed observing different interferences created by the microstructured fiber core section. Different sensitivities to temperature and strain were obtained and, using a matrix method, it is possible to discriminate both physical parameters. Resolutions of +/- 2 degrees C and +/- 11 mu epsilon for the first structure and +/- 2.3 degrees C and +/- 18 mu epsilon for the second one, for temperature and strain, respectively, were attained.
2017
Authors
Gomes, AD; Frazao, O;
Publication
THIRD INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS
Abstract
A microfiber knot resonator integrated in an abrupt taper-based Mach-Zehnder interferometer was used for simultaneous measurement of temperature and refractive index. This compact structure was fabricated using only CO2 laser processing. The transmission spectrum is the combination of the microfiber knot resonator and the Mach-Zehnder interferometer responses. The two different components of the transmission spectrum (the microfiber knot resonator and the MachZehnder interferometer components) present different sensitivities when subjected to physical or chemical parameters. A characterization in temperature, refractive index, and sodium chloride (NaCl) concentration was performed. A simple matrix method was used for simultaneous measurement of temperature and refractive index.
2016
Authors
Andre, RM; Warren Smith, SC; Becker, M; Dellith, J; Rothhardt, M; Zibaii, MI; Latifi, H; Marques, MB; Bartelt, H; Frazao, O;
Publication
OPTICS EXPRESS
Abstract
Optical fiber micro-tips are promising devices for sensing applications in small volume and difficult to access locations, such as biological and biomedical settings. The tapered fiber tips are prepared by dynamic chemical etching, reducing the size from 125 mu m to just a few mu m. Focused ion beam milling is then used to create cavity structures on the tapered fiber tips. Two different Fabry-Perot micro-cavities have been prepared and characterized: a solid silica cavity created by milling two thin slots and a gap cavity. A third multi-cavity structure is fabricated by combining the concepts of solid silica cavity and gap cavity. This micro-tip structure is analyzed using a fast Fourier transform method to demultiplex the signals of each cavity. Simultaneous measurement of temperature and external refractive index is then demonstrated, presenting sensitivities of 15.8 pm/K and -1316 nm/RIU, respectively. (C) 2016 Optical Society of America
The access to the final selection minute is only available to applicants.