2006
Authors
de Oliveira, R; Frazao, O; Santos, JL; Marques, AT;
Publication
ADVANCED MATERIALS FORUM III, PTS 1 AND 2
Abstract
In this study an optic fibre system for health monitoring of fibre reinforced plastics was developed. It is based on the detection of acoustic emission (AE) waves in a loaded material. A low-finesse Fabry-Perot interferometer sensor is used as alternative to the conventional piezoelectric transducers for AE waves sensing. An original procedure for optical fibre sensor interrogation is proposed.
2011
Authors
Tafulo, PAR; Jorge, PAS; Santos, JL; Frazao, O;
Publication
INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS
Abstract
In this paper, two novel hybrid multimode/single mode fiber Fabry-Perot (FP) cavities were compared. The cavities fabricated by chemical etching are presented as high temperature and strain sensors. In order to produce this FP cavity a single mode fiber was spliced to a graded index multimode fiber with 62.5 mu m core diameter. The multimode fiber was cut approximately 150 mu m away from the splice. Then the tip of the fiber containing the multimode fiber segment was dipped into a solution of 48% of HF during 8 minutes, creating a concavity due to the fact that the reaction between HF and the germanium doped fiber core is much faster than the reaction between HF and the pure silica cladding. By this method a concavity of approximately 100 mu m deep was created at the fiber tip. Two different FP cavities can be fabricated. The first cavity is obtained when a spliced with an identical tip concavity fiber (Sensor A) and the second is created when a tip concavity is spliced to a single mode fiber (Sensor B). The Fabry-Perot cavities were tested as a high temperature sensor in the range between room temperature and 800 degrees C and as strain sensors. A reversible shift of the interferometric peaks with temperature allowed to estimate a sensitivity of 0.75 +/- 0.03 pm/degrees C and 0.98 +/- 0.04 pm/degrees C for the sensor A and B respectively. For strain measurement sensor A demonstrated a sensitivity of 1.85 +/- 0.07 pm/mu epsilon and sensor B showed a sensitivity of 3.14 +/- 0.05 pm/mu epsilon. The sensors demonstrated the feasibility of low cost fiber optic sensors for high temperature and strain.
2011
Authors
Silva, S; Frazao, O; Santos, JL; Malcata, FX;
Publication
INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS
Abstract
A simple interrogation technique for refractive index measurement is proposed, using a multimode interference-based fiber tip structure. The fiber probe is a section of a multimode fiber, spliced to a single-mode fiber and interrogated in reflection. The interrogation technique uses two fiber Bragg gratings as discrete optical sources; by means of relative intensity variation of the reflected signals, those sources will provide a measurement of refractive index changes, while taking advantage of the MMI-based fiber tip. The read-out system uses a WDM and two photodetectors to separate both signals. A sensitivity of -5.87/RIU, in the refractive index range 1.30-1.38, was achieved with the proposed configuration.
2011
Authors
Frazao, O; Silva, RM; Santos, JL;
Publication
21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS
Abstract
Two new configurations of high-birefringent fiber loop mirror with an output port probe are proposed. The two configurations used two couplers spliced between them with unbalanced arms and one output port is used as the probe sensor. The difference between them is that the section length of high-birefringent fiber is located between the two couplers (first configuration) or spliced in the output port probe (second configuration). The first new configuration is studied as an optical refractometer and the second configuration is analyzed when the strain and temperature are applied.
2012
Authors
Silva, S; Coelho, L; Santos, JL; Malcata, FX; Becker, M; Rothhardt, M; Bartelt, H; Frazao, O;
Publication
Optics InfoBase Conference Papers
Abstract
An optical fiber sensor based on a tapered-FBG coated with 150 nm-thick Pd film is proposed for hydrogen pressure detection. The FBG was written in a 50 µm-diameter tapered fiber by DUV femtosecond laser technology. A second FBG was inscribed in the untapered fiber region for temperature compensation. The sensing head was able to detect the variation of hydrogen pressure in the range 0-780 kPa and a maximum sensitivity of 0.15 pm/kPa was achieved. © 2012 OSA.
2011
Authors
Santos, JLC; Oliveira, R; Crespo, JG;
Publication
Nanoporous Materials for Energy and the Environment
Abstract
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.