Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Publications

Publications by Marcos Martins

2022

Development of an automated sensor for in-situ continuous monitoring of streambed sediment height of a waterway

Authors
Matos, T; Rocha, JL; Faria, CL; Martins, MS; Henriques, R; Goncalves, LM;

Publication
SCIENCE OF THE TOTAL ENVIRONMENT

Abstract
The sedimentary processes play a major role in every aquatic ecosystem, however, there are few automated options for in-situ monitoring of sediment displacement in the streambed of waterways. We present an automated optical instrument for in-situ continuous monitoring of sediment deposition and erosion of the streambed that requires no calibration. With a production cost of 32euro, power consumption of 300 mu A in sleep mode, and capacity to monitor the bedform of a waterway, the sensor was developed to evaluate the sediment dynamics of coastal areas with a wide spatial and temporal resolution. The novel device is intended to be buried in the sand and uses 32 infrared channels to monitor the streambed sediment height. For testing purposes, a maximum measuring length of 160 mm and 5 mm resolution was chosen, but these values are scalable. Sensors can be built with different ranges and precision according to the needs of the fieldwork. A laboratory experiment was conducted to demonstrate the working principle of the instrument and its behaviour regarding the turbidity originated by suspended sediment and the settling and deposition of the suspended particles. The device was deployed for 119 days in an estuarine area and was able to detect patterns in the sediment deposition and resuspension during the tidal cycles. Also, abnormal events occurred during the experiment as floods and algae blooms. During these events, the sensor was able to record exceptional erosion and sediment deposition rates. The reported automated instrument can be broadly used in sedimentary studies or management and planning of fluvial and maritime infrastructures to provide real-time information about the changes in the bedform of the watersheds.

2022

Development of an Ultraviolet-C Irradiation Room in a Public Portuguese Hospital for Safe Re-Utilization of Personal Protective Respirators

Authors
Padrao, J; Nicolau, T; Felgueiras, HP; Calcada, C; Veiga, MI; Osorio, NS; Martins, MS; Dourado, N; Taveira-Gomes, A; Ferreira, F; Zille, A;

Publication
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH

Abstract
Almost two years have passed since COVID-19 was officially declared a pandemic by the World Health Organization. However, it still holds a tight grasp on the entire human population. Several variants of concern, one after another, have spread throughout the world. The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) omicron variant may become the fastest spreading virus in history. Therefore, it is more than evident that the use of personal protective equipment (PPE) will continue to play a pivotal role during the current pandemic. This work depicts an integrative approach attesting to the effectiveness of ultra-violet-C (UV-C) energy density for the sterilization of personal protective equipment, in particular FFP2 respirators used by the health care staff in intensive care units. It is increasingly clear that this approach should not be limited to health care units. Due to the record-breaking spreading rates of SARS-CoV-2, it is apparent that the use of PPE, in particular masks and respirators, will remain a critical tool to mitigate future pandemics. Therefore, similar UV-C disinfecting rooms should be considered for use within institutions and companies and even incorporated within household devices to avoid PPE shortages and, most importantly, to reduce environmental burdens.

2022

Fracture characterisation of bone-cement bonded joints under mode I loading

Authors
Campos, TD; Barbosa, MLS; Olmos, AAR; Martins, M; Pereira, FAM; De Moura, MFSF; Zille, A; Dourado, N;

Publication
THEORETICAL AND APPLIED FRACTURE MECHANICS

Abstract
Over the years, many techniques have been developed for the stabilisation of bone fractures. The study of the adhesion of bone-to-bone cement is an important step towards the development of new immobilization systems. Although bone cement has been used for more than fifty years, very few studies have been performed regarding the evaluation of fracture properties. In this work, numerical and experimental investigations were conducted to evaluate the strain energy release rate under mode I loading in a bone-cement bonded joint, using the Double Cantilever Beam (DCB) test. Cohesive zone laws were also measured combining the finite element method with non-linear elastic fracture mechanics. This has been made in a cortical bone bonded joint with polymethylmethacrylate (PMMA). Consistent results have been obtained regarding fracture toughness in a widely used bone-to-bone cement joint in many biomedical applications.

2022

A low-cost, low-power and low-size multi-parameter station for real-time and online monitoring of the coastal area

Authors
Matos, T; Rocha, JL; Dinis, H; Faria, CL; Martins, MS; Henriques, R; Goncalves, LM;

Publication
2022 OCEANS HAMPTON ROADS

Abstract
The seashore is the front door to the oceans and the sustain of many societies. However, humans still seem to be unable to unlock new paradigms to project sustainable growth of marine and coastal ecosystems. One of the reasons for this is the lack of knowledge about the natural processes that systematically change their balance. Thus, a new generation of tools is needed to gather data to validate and predict geostatistical models and protect this important resource. This manuscript reports the design and validation of a multi-parameter marine station installed in the estuary of Cavado - Portugal. For the last two years, the station has hosted several own-developed sensors to monitor water parameters, and it was designed to send the monitoring data, in real-time, to a public website so the information can be shared with the communities. So far, the monitoring station has been able to produce data about hydraulic and environmental dynamics, such as water column height or sediment displacement, as well as seasonal events and other extreme phenomena occurrences such as floods. The proposed monitoring system, built in a low-power and low-cost philosophy, aims to allow massive replication all over the coastal areas and to deliver qualitative and quantitative data for better management and planning of the littoral.

2023

Marine Sensors: Recent Advances and Challenges

Authors
Gontalves, L; Martins, MS; Lima, RA; Minas, G;

Publication
SENSORS

Abstract
The ocean has a huge impact on our way of life; therefore, there is a need to monitor and protect its biodiversity [...].

2023

On the evaluation of strain energy release rate of cement-bone bonded joints under mode II loading

Authors
Campos, TD; Barbosa, MLS; Martins, M; Pereira, FAM; de Moura, MFSF; Nguyen, Q; Zille, A; Dourado, N;

Publication
THEORETICAL AND APPLIED FRACTURE MECHANICS

Abstract
Bone cements based on poly(methylmethacrylate) (PMMA) are primarily used in joint replacement surgeries. In the fixation of joint replacement, the self-curing cement fills constitutes a very important interface. To under-stand and improve the interaction between cortical bone and bone cement it is essential to characterize the mechanical properties of cement-bone bonded joints in full detail. In this study, the end-notched flexure test was used in the context of pure mode II fracture characterisation of cement-bone bonded joints. A data reduction scheme based on crack equivalent concept was employed to overcome the difficulties inherent to crack length monitoring during damage propagation. A finite element method combined with a cohesive zone model was first used to validate numerically the adopted method. The procedure was subsequently applied to experimental results to determine the fracture toughness of cement-bone bonded joints under pure mode II loading. The consistency of the obtained results leads to the conclusion that the adopted procedure is adequate to carry out fracture characterisation of these joints under pure mode II loading. The innovative aspect of the present work lies in the application of cohesive zone modelling approach to PMMA-based cement-bone bonded joints.

  • 2
  • 10