Cookies Policy
The website need some cookies and similar means to function. If you permit us, we will use those means to collect data on your visits for aggregated statistics to improve our service. Find out More
Accept Reject
  • Menu
Publications

Publications by CAP

2023

Refractive Index Measurements of Ethanol-Water Binary Liquid Solutions Using a Graded-Index Fiber Tip Sensor

Authors
Soares, L; Cunha, C; Novais, S; Ferreira, A; Frazao, O; Silva, S;

Publication
IEEE SENSORS LETTERS

Abstract
The refractometric analysis of ethanol-water mixtures is hampered because this type of binary solution does not present a linear behavior. In this letter, a multimode graded-index fiber (GIF) tip sensor for the measurement of ethanol in binary liquid solutions of ethanol-water is proposed. The proof is fabricated by the fusion-splicing of a 500 mu m GIF to a single-mode fiber (SMF), and it operates as a refractometric sensor in reflection. To evaluate the prove potential to detected ethanol variations, samples of ethanol-water mixtures were measured at different temperatures (20 degrees C-60 degrees C). The samples have different %(v/v) of ethanol, in a range between 0% and 100%.

2023

A Photo-Thermoelectric Twist to Wireless Energy Transfer: Radial Flexible Thermoelectric Device Powered by a High-Power Laser Beam

Authors
Maia, M; Pires, AL; Rocha, M; Ferreira Teixeira, S; Robalinho, P; Frazao, O; Furtado, C; Califórnia, A; Machado, V; Bogas, S; Ferreira, C; Machado, J; Sousa, L; Luis, UG; San Juan, AMG; Crespo, PO; Medina, FN; Sande, CU; Marino, AC; González, GR; Pereira, AT; Agelet, FA; Jamier, R; Roy, P; Leconte, B; Auguste, JL; Pereira, AM;

Publication
ADVANCED MATERIALS TECHNOLOGIES

Abstract
Systems for wireless energy transmission (WET) are gaining prominence nowadays. This work presents a WET system based on the photo-thermoelectric effect. With an incident laser beam at lambda = 1450 nm, a temperature gradient is generated in the radial flexible thermoelectric (TE) device, with a carbon-based light collector in its center to enhance the photoheating. The three-part prototype presents a unique approach by using a radial TE device with one simple manufacturing process - screen-printing. A TE ink with a polymeric matrix of poly(3,4-ethylenedioxythiophene) polystyrene sulfonate and doped-Poly(vinyl alcohol) with Sb-Bi-Te microparticles is developed (S similar to 33 mu VK-1 and s similar to 10.31 Sm-1), presenting mechanical and electrical stability. Regarding the device, a full electrical analysis is performed, and the influence of the light collector is investigated using thermal tests, spectrophotometry, and numerical simulations. A maximum output voltage (Vout) of similar to 16 mV and maximum power density of similar to 25 mu Wm(-2) are achieved with Plaser = 2 W. Moreover, the device's viability under extreme conditions is explored. At T similar to 180 K, a 25% increase in Vout compared to room-temperature conditions is achieved, and at low pressures (similar to 10(-6) Torr), an increase of 230% is obtained. Overall, this prototype allows the supply of energy at long distances and remote places, especially for space exploration.

2023

Short Pulse Generation in Erbium-Doped Fiber Lasers Using Graphene Oxide as a Saturable Absorber

Authors
Monteiro, CS; Perez Herrera, RA; Silva, SO; Frazão, O;

Publication
Proceedings of the 11th International Conference on Photonics, Optics and Laser Technology, PHOTOPTICS 2023, Lisbon, Portugal, February 16-18, 2023.

Abstract
The use of graphene oxide (GO) as a saturable absorber for short pulses generation in an Erbium-doped fiber laser was studied and demonstrated. The saturable absorber consisted of a thin GO film, with a high concentration of monolayer GO flakes, spray-coated on the end face of a ferrule-connected fiber. By including the saturable absorber in the laser cavity and controlling the intra-cavity polarization, the generation of shortpulsed light was achieved under mode-locking and Q-switching operations. Under mode-locking operation, it was observed a pulse train with a fundamental repetition rate of 1.48 MHz, with a working wavelength centered at 1564.4 nm. In the Q-switch operation, a pulse train with a 12.7 kHz repetition rate and a 14.3 µs pulse duration was attained for a 230-mA pump current. Further investigation showed a linear dependence of the repetition rate with the pump power, attaining frequencies between 12.7 and 14.4 kHz. © 2023 by SCITEPRESS - Science and Technology Publications, Lda.

2023

Optical Fiber Surface Plasmon Resonance for Glucose Detection

Authors
Cunha, C; Silva, S; Coelho, LCC; Frazão, O; Novais, S;

Publication
EPJ Web of Conferences

Abstract
This work proposes a sensor that utilizes a transmission scheme for measuring glucose aqueous solutions based on surface plasmon resonance. A comparison between the performance of two sensors with similar lengths and different diameters is performed. The first sensor comprises a multimode optical fiber with a diameter of 400 µm and a 10 mm middle section of the cladding removed. The second sensor is similar, except that the fiber has a diameter of 600 µm. The sensors were evaluated for their performance in measuring glucose concentrations ranging from 0.0001 to 0.5000 g/mL. The 400 µm sensor demonstrated high sensitivity however, the sensor with a diameter of 600 µm attained a slightly higher maximum sensitivity of 322.0 nm/(g/mL).

2023

NonInvasive Glucose Fiber Sensor Based on Self-Imaging Technique: Proof of Concept

Authors
Cunha, C; Silva, S; Frazão, O; Novais, S;

Publication
EPJ Web of Conferences

Abstract
This paper proposes a proof of concept for a reflective fiber optic sensor based on multimode interference, designed to measure glucose concentrations in aqueous solutions that mimic the range of glucose concentrations found in human saliva. The sensor is fabricated by splicing a short section of coreless silica fiber into a standard single-mode fiber. By studying the principles of multimode interference and Self-imaging it was developed a sensing head that has a total length of 29.1 mm, approximately equal to the second self-image cycle. This sensing head allowed us to detect low concentrations of glucose (ranging from 0 to 268 mg/dl).

2023

How to Use Fiber Optic Sensors for Accurate Absolute Measurements - INVITED

Authors
Frazão, O; Robalinho, P; Vaz, A; Soares, L; Soares, B; Monteiro, C; Novais, S; Silva, S;

Publication
EPJ Web of Conferences

Abstract
The scientific community has been exploring new concepts as a result of the usage of optical fibers as absolute measurement sensors. While cross-sensitivity is a common issue with optical fiber sensors, this issue has been mitigated by simultaneous measurement techniques. But when it comes to absolute measurements, these methods have some limitations. The white light interferometer, which offers a superb solution for a range of applications, especially for absolute temperature measurement, is one of the most often used methods for absolute measurements.

  • 12
  • 234