Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Sobre

Sobre

Tópicos
de interesse
Detalhes

Detalhes

  • Nome

    Cláudia Vanessa Brito
  • Cargo

    Investigador Auxiliar
  • Desde

    01 outubro 2018
004
Publicações

2024

A Distributed Computing Solution for Privacy-Preserving Genome-Wide Association Studies

Autores
Brito, C; Ferreira, P; Paulo, J;

Publicação

Abstract
AbstractBreakthroughs in sequencing technologies led to an exponential growth of genomic data, providing unprecedented biological in-sights and new therapeutic applications. However, analyzing such large amounts of sensitive data raises key concerns regarding data privacy, specifically when the information is outsourced to third-party infrastructures for data storage and processing (e.g., cloud computing). Current solutions for data privacy protection resort to centralized designs or cryptographic primitives that impose considerable computational overheads, limiting their applicability to large-scale genomic analysis.We introduce Gyosa, a secure and privacy-preserving distributed genomic analysis solution. Unlike in previous work, Gyosafollows a distributed processing design that enables handling larger amounts of genomic data in a scalable and efficient fashion. Further, by leveraging trusted execution environments (TEEs), namely Intel SGX, Gyosaallows users to confidentially delegate their GWAS analysis to untrusted third-party infrastructures. To overcome the memory limitations of SGX, we implement a computation partitioning scheme within Gyosa. This scheme reduces the number of operations done inside the TEEs while safeguarding the users’ genomic data privacy. By integrating this security scheme inGlow, Gyosaprovides a secure and distributed environment that facilitates diverse GWAS studies. The experimental evaluation validates the applicability and scalability of Gyosa, reinforcing its ability to provide enhanced security guarantees. Further, the results show that, by distributing GWASes computations, one can achieve a practical and usable privacy-preserving solution.

2024

To FID or not to FID: Applying GANs for MRI Image Generation in HPC

Autores
Cepa, B; Brito, C; Sousa, A;

Publicação

Abstract
AbstractWith the rapid growth of Deep Learning models and neural networks, the medical data available for training – which is already significantly less than other types of data – is becoming scarce. For that purpose, Generative Adversarial Networks (GANs) have received increased attention due to their ability to synthesize new realistic images. Our preliminary work shows promising results for brain MRI images; however, there is a need to distribute the workload, which can be supported by High-Performance Computing (HPC) environments. In this paper, we generate 256×256 MRI images of the brain in a distributed setting. We obtained an FIDRadImageNetof 10.67 for the DCGAN and 23.54 for the WGAN-GP, which are consistent with results reported in several works published in this scope. This allows us to conclude that distributing the GAN generation process is a viable option to overcome the computational constraints imposed by these models and, therefore, facilitate the generation of new data for training purposes.

2024

Mastering Artifact Correction in Neuroimaging Analysis: A Retrospective Approach

Autores
Oliveira, A; Cepa, B; Brito, C; Sousa, A;

Publicação

Abstract
The correction of artifacts in Magnetic Resonance Imaging (MRI) is increasingly relevant as voluntary and involuntary artifacts can hinder data acquisition. Reverting from corrupted to artifact-free images is a complex task. Deep Learning (DL) models have been employed to preserve data characteristics and to identify and correct those artifacts. We propose MOANA, a novel DL-based solution to correct artifacts in multi-contrast brain MRI scans. MOANA offers two models: the simulation and the correction models. The simulation model introduces perturbations similar to those occurring in an exam while preserving the original image as ground truth; this is required as publicly available datasets rarely have motion-corrupted images. It allows the addition of three types of artifacts with different degrees of severity. The DL-based correction model adds a fourth contrast to state-of-the-art solutions while improving the overall performance of the models. MOANA achieved the highest results in the FLAIR contrast, with a Structural Similarity Index Measure (SSIM) of 0.9803 and a Normalized Mutual Information (NMI) of 0.8030. With this, the MOANA model can correct large volumes of images in less time and adapt to different levels of artifact severity, allowing for better diagnosis.

2024

Mastering Artifact Correction in Neuroimaging Analysis: A Retrospective Approach

Autores
Oliveira, A; Cepa, B; Brito, C; Sousa, A;

Publicação

Abstract
The correction of artifacts in Magnetic Resonance Imaging (MRI) is increasingly relevant as voluntary and involuntary artifacts can hinder data acquisition. Reverting from corrupted to artifact-free images is a complex task. Deep Learning (DL) models have been employed to preserve data characteristics and to identify and correct those artifacts. We propose MOANA, a novel DL-based solution to correct artifacts in multi-contrast brain MRI scans. MOANA offers two models: the simulation and the correction models. The simulation model introduces perturbations similar to those occurring in an exam while preserving the original image as ground truth; this is required as publicly available datasets rarely have motion-corrupted images. It allows the addition of three types of artifacts with different degrees of severity. The DL-based correction model adds a fourth contrast to state-of-the-art solutions while improving the overall performance of the models. MOANA achieved the highest results in the FLAIR contrast, with a Structural Similarity Index Measure (SSIM) of 0.9803 and a Normalized Mutual Information (NMI) of 0.8030. With this, the MOANA model can correct large volumes of images in less time and adapt to different levels of artifact severity, allowing for better diagnosis.

2024

MAC: An Artifact Correction Framework for Brain MRI based on Deep Neural Networks

Autores
Oliveira, A; Cepa, B; Brito, C; Sousa, A;

Publicação

Abstract
AbstractThe correction of artifacts in Magnetic Resonance Imaging (MRI) is crucial due to physiological phenomena and technical issues affecting diagnostic quality. Reverting from corrupted to artifact-free images is a complex task. Deep Learning (DL) models have been employed to preserve data characteristics and to identify and correct those artifacts. We proposeMAC, a novel DL-based solution to correct artifacts in multi-contrast brain MRI scans.MACoffers two models: the simulation and the correction models. The simulation model introduces perturbations similar to those occurring in an exam while preserving the original image as ground truth; this is required as publicly available datasets rarely have motion-corrupted images. It allows the addition of three types of artifacts with different degrees of severity. The DL-based correction model adds a fourth contrast to state-of-the-art solutions while improving the overall performance of the models.MACachieved the highest results in the FLAIR contrast, with a Structural Similarity Index Measure (SSIM) of 0.9803 and a Normalized Mutual Information (NMI) of 0.8030. Moreover, the model reduced training time by 63% compared to its predecessor.MACmodel can correct large volumes of images faster and adapt to different levels of artifact severity than current state-ofthe-art models, allowing for better diagnosis.