Refractometric sensitivity of Bloch surface waves : perturbation theory calculation and experimental validation

Autores
Dias, BS; De Almeida, JMMM; Coelho, LCC;

Publicação
OPTICS LETTERS

Abstract
The sensitivity of one-dimensional Bloch surface wave (BSW) sensors to external refractive index variations using Kretschmann's configuration is calculated analytically by employing first-order perturbation theory for both TE and TM modes. This approach is then validated by com- parison with both transfer matrix method simulations and experimental results for a chosen photonic crystal structure. Experimental sensitivities of (8.4 +/- 0.2)x102 and (8.4 +/- 0.4)x102 nm/RIU were obtained for the TE and TM BSW modes, corresponding to errors of 0.02% and 4%, respectively, when comparing with the perturbation the- ory approach. These results provide interesting insights into photonic crystal design for Bloch surface wave sensing by casting light into the important parameters related with sen- sor performance.(c) 2023 Optica Publishing Group

2022

Cavity length dependence on strain sensitivity for Fabry-Perot sensors

Autores
Rodrigues, AV; Reis, J; Martins, AJM; Monteiro, CS; Silva, SO; Caridade, CMR; Tavares, SO; Frazao, O;

Publicação
MICROWAVE AND OPTICAL TECHNOLOGY LETTERS

Abstract
This study presents the dependence of strain sensitivity on cavity length in conventional Fabry-Perot (F-P) sensors. A high number of F-P sensors were required and to ensure their reproducibility, a manufacturing process was developed to obtain similar sensors but with different types of lengths. A hollow-core silica tube was used to fabricate several F-P cavities by fusion splicing it between two sections of SMF28 fiber. The fabricated F-P has a varying length ranging from 15 to 2500 mu m. The cavities were measured under a microscope and the reflected spectrum was acquired for each one. Strain measurements were performed for a maximum strain of 1000 mu epsilon. The strain sensitivity showed a highly linear correlation with increment lambda(FSR). Small length variations for short cavities heavily affect the FSR value. The smallest and longest cavities present sensitivities of 8.71 and 2.68 pm/mu epsilon, respectively. Thermal characterization for low- and high-temperature regimes was also performed and is constant for tested sensors.

2022

Femtosecond laser micromachining of suspended silica-core liquid-cladding waveguides inside a microfluidic channel

Autores
Maia, JM; Viveiros, D; Amorim, VA; Marques, PVS;

Publicação
OPTICS AND LASERS IN ENGINEERING

Abstract
This work addresses the fabrication of straight silica-core liquid-cladding suspended waveguides inside a microfluidic channel through fs-laser micromachining. These structures enable the reconfiguration of the waveguide's mode profile and enhance the evanescent interaction between light and analyte. Further, their geometry resembles a tapered optical fiber with the added advantage of being monolithically integrated within a microfluidic platform. The fabrication process includes an additional post-processing thermal treatment responsible for smoothening the waveguide surface and reshaping it into a circular cross-section. Suspended waveguides with a minimum core diameter of 3.8 mu m were fabricated. Their insertion losses can be tuned and are mainly affected by mode mismatch between the coupling and suspended waveguides. The transmission spectrum was studied and it was numerically confirmed that it consists of interference between the guided LP01 mode and uncoupled light and of modal interference between the LP01 and LP02 modes.

2022

Differential Refractometric Biosensor for Reliable Human IgG Detection: Proof of Concept

Autores
Mendes, JP; Coelho, LCC; Jorge, PAS; Pereira, CM;

Publicação
BIOSENSORS-BASEL

Abstract
A new sensing platform based on long-period fiber gratings (LPFGs) for direct, fast, and selective detection of human immunoglobulin G (IgG; Mw = 150 KDa) was developed and characterized. The transducer's high selectivity is based on the specific interaction of a molecularly imprinted polymer (MIPs) design for IgG detection. The sensing scheme is based on differential refractometric measurements, including a correction system based on a non-imprinted polymer (NIP)-coated LPFG, allowing reliable and more sensitive measurements, improving the rejection of false positives in around 30%. The molecular imprinted binding sites were performed on the surface of a LPFG with a sensitivity of about 130 nm/RIU and a FOM of 16 RIU-1. The low-cost and easy to build device was tested in a working range from 1 to 100 nmol/L, revealing a limit of detection (LOD) and a sensitivity of 0.25 nmol/L (0.037 mu g/mL) and 0.057 nm.L/nmol, respectively. The sensor also successfully differentiates the target analyte from the other abundant elements that are present in the human blood plasma.

2022

Invasive and minimally invasive optical detection of pigment accumulation in brain cortex

Autores
Oliveira, LR; Gonçalves, TM; Pinheiro, MR; Fernandes, LE; Martins, IS; Silva, HF; Oliveira, HP; Tuchin, VV;

Publicação
Journal of Biomedical Photonics and Engineering

Abstract
The estimation of the spectral absorption coefficient of biological tissues provides valuable information that can be used in diagnostic procedures. Such estimation can be made using direct calculations from invasive spectral measurements or though machine learning algorithms based on noninvasive or minimally invasive spectral measurements. Since in a noninvasive approach, the number of measurements is limited, an exploratory study to investigate the use of artificial generated data in machine learning techniques was performed to evaluate the spectral absorption coefficient of the brain cortex. Considering the spectral absorption coefficient that was calculated directly from invasive measurements as reference, the similar spectra that were estimated through different machine learning approaches were able to provide comparable information in terms of pigment, DNA and blood contents in the cortex. The best estimated results were obtained based only on the experimental measurements, but it was also observed that artificially generated spectra can be used in the estimations to increase accuracy, provided that a significant number of experimental spectra are available both to generate the complementary artificial spectra and to estimate the resulting absorption spectrum of the tissue. © 2022 Journal of Biomedical Photonics & Engineering. © J-BPE.

2022

Optical Strain Gauge Prototype Based on a High Sensitivity Balloon-like Interferometer and Additive Manufacturing

Autores
Cardoso, VHR; Caldas, P; Giraldi, MTR; Frazao, O; Costa, JCWA; Santos, JL;

Publicação
SENSORS

Abstract
An optical strain gauge based on a balloon-like interferometer structure formed by a bent standard single-mode fiber combined with a 3D printer piece has been presented and demonstrated, which can be used to measure displacement. The interferometer has a simple and compact size, easy fabrication, low cost, and is repeatable. The sensor is based on the interference between the core and cladding modes. This is caused by the fiber's curvature because when light propagates through the curved balloon-shaped interferometer region, a portion of it will be released from the core limitation and coupled to the cladding. The balloon has an axial displacement as a result of how the artwork was constructed. The sensor head is sandwiched between two cantilevers such that when there is a displacement, the dimension associated with the micro bend is altered. The sensor response as a function of displacement can be determined using wavelength shift or intensity change interrogation techniques. Therefore, this optical strain gauge is a good option for applications where structure displacement needs to be examined. The sensor presents a sensitivity of 55.014 nm for displacement measurements ranging from 0 to 10 mm and a strain sensitivity of 500.13 pm/mu epsilon.