2022
Autores
Mendes, JP; Coelho, LCC; Jorge, PAS; Pereira, CM;
Publicação
BIOSENSORS-BASEL
Abstract
A new sensing platform based on long-period fiber gratings (LPFGs) for direct, fast, and selective detection of human immunoglobulin G (IgG; Mw = 150 KDa) was developed and characterized. The transducer's high selectivity is based on the specific interaction of a molecularly imprinted polymer (MIPs) design for IgG detection. The sensing scheme is based on differential refractometric measurements, including a correction system based on a non-imprinted polymer (NIP)-coated LPFG, allowing reliable and more sensitive measurements, improving the rejection of false positives in around 30%. The molecular imprinted binding sites were performed on the surface of a LPFG with a sensitivity of about 130 nm/RIU and a FOM of 16 RIU-1. The low-cost and easy to build device was tested in a working range from 1 to 100 nmol/L, revealing a limit of detection (LOD) and a sensitivity of 0.25 nmol/L (0.037 mu g/mL) and 0.057 nm.L/nmol, respectively. The sensor also successfully differentiates the target analyte from the other abundant elements that are present in the human blood plasma.
2022
Autores
Ferreira, MFS; Capela, D; Silva, NA; Goncalves, F; Lima, A; Guimaraes, D; Jorge, PAS;
Publicação
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY
Abstract
Laser-induced breakdown spectroscopy allows fast chemical analysis of light elements without significant sample preparation, turning it into a promising technique for on-site mining operations. Still, the performance for quantification purposes remains its major caveat, obstructing a broader application of the technique. In this work, we present an extensive comparison of the performances of distinct algorithms for quantification of Lithium in a mining prospection stage, using spectra acquired with both a commercial handheld device and a laboratory prototype. Covering both linear and non-linear methodologies, the results show that, when covering a wide range of concentrations typical on a mining operation, non-linear methodologies manage to achieve errors compatible with a semi-quantitative performance, offering performances better than those obtained with linear methods, which are more affected by saturation and matrix effects. The findings enclosed offer support for future applications in the field and may possibly be generalized for other elements of interest in similar mining environments.
2022
Autores
Vasconcelos, H; Matias, A; Mendes, J; Arahjo, J; Dias, B; Jorge, PAS; Saraivaa, C; Coelho, LCC; de Almeida, JMMM;
Publicação
OPTICAL SENSING AND DETECTION VII
Abstract
A strategy for the detection of H2O2 as a milk adulterant using a single shot membrane sensor, is presented. Direct quantitative evaluation of H2O2 in raw, skimmed, semi-skimmed and whole milk was carried out based on a chemiluminescence reaction with luminol. For H2O2 water solutions a linear response was attained from 0.0001% to 0.007 %w/w, with a limit of detection of 3x10(-5) %w/w. A coefficient of determination, R-2, greater than 0.97 was achieved, with a relative standard deviation (RSD) not exceeding 10%. In the analyzed milk samples, the lowest H2O2 concentration detected was 0.001% w/w for raw and for skim milk and 0.002%w/w for, semi-skimmed and whole milk. The presented method is original, sensitive, rapid, and cost-effective. Due to the achieved sensitivity the method has great potential to be used for H2O2 detection in diverse areas, such as environmental monitoring and food quality.
2022
Autores
Vasconcelos, HCASG; de Almeida, JMMM; Mendes, JP; Dias, B; Jorge, PAD; Saraiva, CMT; Coelho, LCC;
Publicação
IEEE SENSORS JOURNAL
Abstract
Biogenic amines (BAs) are compounds found in a vast range of food products. In recent years, there has been a crescent awareness toward food safety, followed by an increase in food regulations. Long-period fiber gratings (LPFGs) coated with titanium dioxide (TiO2) were used to monitor the optical properties of a layer of poly(ethylene-co-vinyl acetate) (PEVA) doped with maleic anhydride (MA), which was polymerized on top of TiO2. This hydrophobic polymeric structure is permeable to BA, which causes a steady increase in its effective refractive index (RI) causing a wavelength shift in the coated LPFG attenuation band. LPFG wavelength shift was observed and measured for the monoamine tyramine (TYR), to the diamines, putrescine (PUT), cadaverine (CAD), histamine (HIS), and tryptamine (TRYP), and to the polyamines, spermidine (SPED), and spermine (SPEM). It was determined that, while PEVA-coated devices present a residual sensitivity to BA, the MA greatly increases it. In fact, for PEVA only coated LPFGs, the sensitivities of 1.45 +/- 0.11, 0.97 +/- 0.05, 0.46 +/- 0.08, and 0.94 +/- 0.09 nmM-1 for PUT, CAD, HIS, and TYR, respectively, were measured. However, for PEVA-doped MA-coated LPFGs, the sensitivities are 3.34 +/- 0.13, 3.06 +/- 0.11, 2.62 +/- 0.14, and 3.65 +/- 0.23 nmM-1 for PUT, CAD, HIS, and TYR, respectively. Thus, the RI of PEVA increases with BAs in- diffusion, and MA doping further enhances the PEVA sensitivity to BA. The proposed sensor is expected to play a part in the further development of a biosensor for the quantification of BA in real foodstuff, providing a methodology for quality control.
2022
Autores
Vasconcelos, H; De Almeida, JMMM; Mendes, J; Dias, B; Jorge, PAS; Saraiva, C; Coelho, LCC;
Publicação
Optics InfoBase Conference Papers
Abstract
Long period fiber gratings coated with TiO2 and poly(ethylene-co-vinyl acetate) (PEVA), a polymeric structure permeable biogenic amines found in foodstuff, were used to detect these compounds through the wavelength shift of its attenuation band. © 2022 The Author(s).
2022
Autores
Rocha, V; Oliveira, J; Guerreiro, A; Jorge, PAS; Silva, NA;
Publicação
EPJ Web of Conferences
Abstract
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.