2017
Autores
Lima, R; Tavares, R; Silva, SO; Abreu, P; Restivo, MT; Frazao, O;
Publicação
2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS)
Abstract
A cantilever structure in 3D printed based on a fiber Bragg grating (FBG) sensor embedded in polymer material is proposed. The FBG sensor was embedded in 3D printed coating and was tested under three physical parameters: displacement, temperature and vibration. The sensor was tested in displacement in two different regions of the cantilever, namely, on its midpoint and end point. The maximum displacement sensitivity achieved was (3 +/- 0.1) pm/mm for end point displacement, and a temperature sensitivity of (30 +/- 1) pm/degrees C was also attained. In the case of vibration measurements it was possible to obtain a 10.23Hz-low frequency oscillation.
2017
Autores
Silva, S; Frazao, O;
Publicação
PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PHOTONICS, OPTICS AND LASER TECHNOLOGY (PHOTOPTICS)
Abstract
A brief review in the fibre cavity ring-down (CRD) technique is presented. It addresses the latest developments in CRD technique for sensing applications, undergone at INESC TEC. The CRD is based on the conventional configuration with the possibility of adding amplification in order to compensate the output signal losses induced by the sensing head. The results obtained for strain, curvature and refractive index sensing are presented, corresponding to distinct sensing structures, namely, a chirped fibre Bragg grating (FBG), a long period grating (LPG) and a multimode interference (MMI) based sensor.
2017
Autores
Monteiro, C; Silva, S; Frazao, O;
Publicação
IEEE PHOTONICS TECHNOLOGY LETTERS
Abstract
Two different sensing structures based on a hollow microsphere Fabry-Perot cavity are proposed. The hollow spheroidal cavities are fabricated resorting only to fusion splicing. The first structure is based on a hollow microsphere located at the fiber end and works as a probe sensor. The structure was subjected to lateral load pressure and presents a sensitivity of 1.56 +/- 0.01 nm/N. The second proposed sensor relies on an in-line hollow microsphere. The sensing structure allows the detection of lateral loading, with a sensitivity of 2.62 +/- 0.02 nm/N, as well as strain detection, with a sensitivity of 4.66 +/- 0.03 pm/mu epsilon. The two proposed sensors present similar response when subjected to temperature and have low thermal sensitivity.
2017
Autores
Silva, S; Frazao, O;
Publicação
2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS)
Abstract
This work presents a multimode interference-based fiber sensor in a cavity ring-down system for sensing temperature-induced refractive index (RI) changes of water. The sensing head is based in multimodal interference (MMI) and it was placed inside the fiber loop cavity of the CRD system. A modulated laser source was used to send pulses down into the fiber loop cavity and an erbium-doped fiber amplifier (EDFA) was placed in the fiber ring to provide an observable signal with a reasonable decay time. The behavior of the sensing head to temperature was studied due to its intrinsic sensitivity to said parameter - a sensitivity of -1.6 10(-9) s/C was attained. This allowed eliminating the temperature component from RI measurement of water and a linear sensitivity of 580 mu s/RIU in the RI range of 1.324-1.331 was obtained.
2017
Autores
Gomes, AD; Frazao, O;
Publicação
THIRD INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS
Abstract
A microfiber knot resonator integrated in an abrupt taper-based Mach-Zehnder interferometer was used for simultaneous measurement of temperature and refractive index. This compact structure was fabricated using only CO2 laser processing. The transmission spectrum is the combination of the microfiber knot resonator and the Mach-Zehnder interferometer responses. The two different components of the transmission spectrum (the microfiber knot resonator and the MachZehnder interferometer components) present different sensitivities when subjected to physical or chemical parameters. A characterization in temperature, refractive index, and sodium chloride (NaCl) concentration was performed. A simple matrix method was used for simultaneous measurement of temperature and refractive index.
2017
Autores
Ferreira, MFS; Statkiewiez Barabach, G; Kowal, D; Mergo, P; Urbanczyk, W; Frazao, O;
Publicação
OPTICS COMMUNICATIONS
Abstract
The use of a polymer fiber as a refractive index sensor is proposed. A fiber Bragg grating is inscribed near the fiber tip and the fiber is cut shorter thus creating a Fabry-Perot cavity. The reflections between the fiber Bragg grating and the fiber end-face create a Fabry-Perot interferometer. The sensor was characterized to refractive index changes at constant temperature and to temperature at constant refractive index using a fast Fourier transform analysis of the interference signal. The sensor revealed a sensitivity of-1. 94 RIU-1 with a resolution of lx10(-3)RITJ and low sensitivity to temperature, with a cross sensitivity to temperature of 3. 6x10(-4)RIU/degrees C.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.