2024
Autores
Elsaid, M; Pessoa, LM;
Publicação
2024 18TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP
Abstract
Reconfigurable Intelligent Surfaces (RISs) are in significant focus within 6G research. However, RISs face a power consumption challenge in the reconfigurable elements which may restrict its future scale-up to large areas. We address this issue by proposing a unit cell based on a non-volatile memristor-based switching mechanism. A 1-bit memristor-based reconfigurable RIS unit cell was designed in the Ka-band, and validated using CST and HFSS simulation platforms. The required control circuit to enable the digital control of the memristor has also been proposed. The proposed unit cell achieves losses of less than 1 dB over a frequency band of 25 - 28.3 GHz and a phase difference of 180 degrees +/- 20 degrees at a central frequency of 26.7 GHz, with an operational bandwidth of approximately 1 GHz. Furthermore, an exemplary 16x16 RIS was designed and simulated based on the proposed unit cell to demonstrate its capability to achieve beam steering.
2024
Autores
Fernandes, L; Pereira, T; Oliveira, HP;
Publicação
2024 IEEE 37TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, CBMS 2024
Abstract
Currently, lung cancer is one of the deadliest diseases that affects millions of people globally. However, Artificial Intelligence is being increasingly integrated with healthcare practices, with the goal to aid in the early diagnosis of lung cancer. Although such methods have shown very promising results, they still lack transparency to the user, which consequently could make their generalised adoption a challenging task. Therefore, in this work we explore the use of post-hoc explainable methods, to better understand the inner-workings of an already established multitasking framework that executes the segmentation and the classification task of lung nodules simultaneously. The idea behind such study is to understand how a multitasking approach impacts the model's performance in the lung nodule classification task when compared to single-task models. Our results show that the multitasking approach works as an attention mechanism by aiding the model to learn more meaningful features. Furthermore, the multitasking framework was able to achieve a better performance in regard to the explainability metric, with an increase of 7% when compared to our baseline, and also during the classification and segmentation task, with an increase of 4.84% and 15.03%; for each task respectively, when also compared to the studied baselines.
2024
Autores
Kazemi, A; Rasouli Saravani, A; Gharib, M; Albuquerque, T; Eslami, S; Schüffler, J;
Publicação
Computers in Biology and Medicine
Abstract
The incidence of colorectal cancer (CRC), one of the deadliest cancers around the world, is increasing. Tissue microenvironment (TME) features such as tumor-infiltrating lymphocytes (TILs) can have a crucial impact on diagnosis or decision-making for treating patients with CRC. While clinical studies showed that TILs improve the host immune response, leading to a better prognosis, inter-observer agreement for quantifying TILs is not perfect. Incorporating machine learning (ML) based applications in clinical routine may promote diagnosis reliability. Recently, ML has shown potential for making progress in routine clinical procedures. We aim to systematically review the TILs analysis based on ML in CRC histological images. Deep learning (DL) and non-DL techniques can aid pathologists in identifying TILs, and automated TILs are associated with patient outcomes. However, a large multi-institutional CRC dataset with a diverse and multi-ethnic population is necessary to generalize ML methods. © 2024 Elsevier Ltd
2024
Autores
Moreira, G; Loureiro, JP; Teixeira, B; Campos, R;
Publicação
2024 IEEE 22nd Mediterranean Electrotechnical Conference, MELECON 2024
Abstract
Underwater wireless communications play a significant role in the Blue Economy, supporting the operations of sensing platforms like Autonomous Surface Vehicles (ASVs) and Autonomous Underwater Vehicles (AUVs). These platforms require reliable and fast communications to transmit the extensive data gathered without surfacing. Yet, the ocean poses challenges to signal propagation, restricting communications to high bitrate at short ranges via optical and RF, or low bitrate at long distances using acoustic communications.This paper introduces Aquacom, a multimodal manager for underwater communications that integrates acoustic, RF, and optical communnications, ensuring seamless handover between technologies and link aggregation to enhance network performance. Upon validation in freshwater tank lab tests, Aquacom demonstrated the capability for switching interfaces without data loss and effective link aggregation through the simultaneous use of multiple wireless interfaces. © 2024 IEEE.
2024
Autores
Dani, M; Rio Torto, I; Alaniz, S; Akata, Z;
Publicação
PATTERN RECOGNITION, DAGM GCPR 2023
Abstract
Post-hoc explanation methods have often been criticised for abstracting away the decision-making process of deep neural networks. In this work, we would like to provide natural language descriptions for what different layers of a vision backbone have learned. Our DeViL method generates textual descriptions of visual features at different layers of the network as well as highlights the attribution locations of learned concepts. We train a transformer network to translate individual image features of any vision layer into a prompt that a separate off-the-shelf language model decodes into natural language. By employing dropout both per-layer and per-spatial-location, our model can generalize training on image-text pairs to generate localized explanations. As it uses a pre-trained language model, our approach is fast to train and can be applied to any vision backbone. Moreover, DeViL can create open-vocabulary attribution maps corresponding to words or phrases even outside the training scope of the vision model. We demonstrate that DeViL generates textual descriptions relevant to the image content on CC3M, surpassing previous lightweight captioning models and attribution maps, uncovering the learned concepts of the vision backbone. Further, we analyze fine-grained descriptions of layers as well as specific spatial locations and show that DeViL outperforms the current state-of-the-art on the neuron-wise descriptions of the MILANNOTATIONS dataset.
2024
Autores
Neto, PC; Montezuma, D; Oliveira, SP; Oliveira, D; Fraga, J; Monteiro, A; Monteiro, J; Ribeiro, L; Gonçalves, S; Reinhard, S; Zlobec, I; Pinto, IM; Cardoso, JS;
Publicação
NPJ PRECISION ONCOLOGY
Abstract
Considering the profound transformation affecting pathology practice, we aimed to develop a scalable artificial intelligence (AI) system to diagnose colorectal cancer from whole-slide images (WSI). For this, we propose a deep learning (DL) system that learns from weak labels, a sampling strategy that reduces the number of training samples by a factor of six without compromising performance, an approach to leverage a small subset of fully annotated samples, and a prototype with explainable predictions, active learning features and parallelisation. Noting some problems in the literature, this study is conducted with one of the largest WSI colorectal samples dataset with approximately 10,500 WSIs. Of these samples, 900 are testing samples. Furthermore, the robustness of the proposed method is assessed with two additional external datasets (TCGA and PAIP) and a dataset of samples collected directly from the proposed prototype. Our proposed method predicts, for the patch-based tiles, a class based on the severity of the dysplasia and uses that information to classify the whole slide. It is trained with an interpretable mixed-supervision scheme to leverage the domain knowledge introduced by pathologists through spatial annotations. The mixed-supervision scheme allowed for an intelligent sampling strategy effectively evaluated in several different scenarios without compromising the performance. On the internal dataset, the method shows an accuracy of 93.44% and a sensitivity between positive (low-grade and high-grade dysplasia) and non-neoplastic samples of 0.996. On the external test samples varied with TCGA being the most challenging dataset with an overall accuracy of 84.91% and a sensitivity of 0.996.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.