Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

Publicações por CTM

2015

On the impact of timer resolution in the efficiency optimization of synchronous buck converters

Autores
Amaral, P; Duarte, C; Costa, P;

Publicação
International Journal of Power Electronics and Drive Systems

Abstract
Excessive dead time in complementary switches causes significant energy losses in DC-DC power conversion. The optimization of dead time prevents the degradation of overall efficiency by minimizing the body diode conduction of power switches and, as a consequence, also reduces reverse recovery losses. The present work aims at analyzing the influence of one of the most important characteristics of a digital controller, the timer resolution, in the context of dead-time optimization for synchronous buck converters. In specific, the analysis quantifies the efficiency dependency on the timer resolution, in a parameter set that comprises duty-cycle and dead-time, and also converter frequency and analog-to-digital converter accuracy. Based on a sensorless optimization strategy, the relationship between all these limiting factors is described, such as the number of bits of timer and analog-to-digital converter. To validate our approach experimental results are provided using a 12-to-1.8V DC-DC converter, controlled by low- and high-resolution pulse-width modulation signals generated with an XMC4200 microcontroller from Infineon Technologies. The measured results are consistent with our analysis, which predicts the power efficiency improvements not only with a fixed dead time approach, but also with the increment of timer resolution.

2015

A Fuzzy C-Means Algorithm for Fingerprint Segmentation

Autores
Ferreira, PM; Sequeira, AF; Rebelo, A;

Publicação
PATTERN RECOGNITION AND IMAGE ANALYSIS (IBPRIA 2015)

Abstract
Fingerprint segmentation is a crucial step of an automatic fingerprint identification system, since an accurate segmentation promote both the elimination of spurious minutiae close to the foreground boundaries and the reduction of the computation time of the following steps. In this paper, a new, and more robust fingerprint segmentation algorithm is proposed. The main novelty is the introduction of a more robust binarization process in the framework, mainly based on the fuzzy C-means clustering algorithm. Experimental results demonstrate significant benchmark progress on three existing FVC datasets.

2015

Novel methods for pulse wave velocity measurement

Autores
Pereira, T; Correia, C; Cardoso, J;

Publicação
Journal of Medical and Biological Engineering

Abstract
The great incidence of cardiovascular (CV) diseases in the world spurs the search for new solutions to enable an early detection of pathological processes and provides more precise diagnosis based in multi-parameters assessment. The pulse wave velocity (PWV) is considered one of the most important clinical parameters for evaluate the CV risk, vascular adaptation, and therapeutic efficacy. Several studies were dedicated to find the relationship between PWV measurement and pathological status in different diseases, and proved the relevance of this parameter. The commercial devices dedicate to PWV estimation make a regional assessment (measured between two vessels), however a local measurement is more precise evaluation of artery condition, taking into account the differences in the structure of arteries. Moreover, the current devices present some limitations due to the contact nature. Emerging trends in CV monitoring are moving away from more invasive technologies to non-invasive and non-contact solutions. The great challenge is to explore the new instrumental solutions that allow the PWV assessment with fewer approximations for an accurately evaluation and relatively inexpensive techniques in order to be used in the clinical routine. © The Author(s) 2015.

2015

Correlation Study Between Blood Pressure And Pulse Transit Time

Autores
Pereira, T; Sanches, R; Reis, P; Pego, J; Simoes, R;

Publicação
2015 IEEE 4TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG)

Abstract
Blood pressure (BP) determination is a fundamental parameter in cardiovascular assessment. The gold standard method to measure BP is based on the inflatable arm cuff, however has several disadvantages for continuous monitoring. New techniques were developed to overcome these limitations using correlations between the pulse transit time (PTT) and BP. This work draws attention to the PTT rationale using several methods. In order to determine the PTT, an electrocardiogram (ECG) was used combined with multiple photoplethysmography (PPG) sensors applied to different arm locations, these signals were acquired with a bioPLUX device. The Ultrassound system (SonoSite Edge) was used to measure the artery diameter. As reference, BP was measured using a cuff- based sphygmomanometric device. Measurements were performed in a study population of 36 volunteers. The correlation coefficient for DBP determined and DBP measured was r = 0,689. The results suggest PTT deduced from different locations can be used to measure BP.

2015

Novel Methods for Pulse Wave Velocity Measurement

Autores
Pereira, T; Correia, C; Cardoso, J;

Publicação
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING

Abstract
The great incidence of cardiovascular (CV) diseases in the world spurs the search for new solutions to enable an early detection of pathological processes and provides more precise diagnosis based in multi-parameters assessment. The pulse wave velocity (PWV) is considered one of the most important clinical parameters for evaluate the CV risk, vascular adaptation, and therapeutic efficacy. Several studies were dedicated to find the relationship between PWV measurement and pathological status in different diseases, and proved the relevance of this parameter. The commercial devices dedicate to PWV estimation make a regional assessment (measured between two vessels), however a local measurement is more precise evaluation of artery condition, taking into account the differences in the structure of arteries. Moreover, the current devices present some limitations due to the contact nature. Emerging trends in CV monitoring are moving away from more invasive technologies to non-invasive and non-contact solutions. The great challenge is to explore the new instrumental solutions that allow the PWV assessment with fewer approximations for an accurately evaluation and relatively inexpensive techniques in order to be used in the clinical routine.

2015

Arterial pulse pressure waveform monitoring by novel optical probe

Autores
Pereira, T; Pereira, TS; Santos, H; Correia, C; Cardoso, J;

Publicação
INTERNATIONAL JOURNAL OF CARDIOLOGY

Abstract

  • 180
  • 324