Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

Publicações por Luís Carlos Coelho

2010

Lowering the low-energy threshold of xenon detectors

Autores
Sorensen, P; Angle, J; Aprile, E; Arneodo, F; Baudis, L; Bernstein, A; Bolozdynya, A; Coelho, LCC; Dahl, CE; DeViveiros, L; Ferella, AD; Fernandes, LMP; Fiorucci, S; Gaitskell, RJ; Giboni, KL; Gomez, R; Hasty, R; Kastens, L; Kwong, J; Lopes, JAM; Madden, N; Manalaysay, A; Manzur, A; McKinsey, DN; Monzani, ME; Ni, K; Oberlack, U; Orboeck, J; Plante, G; Santorelli, R; Dos Santos, JMF; Schulte, S; Shagin, P; Shutt, T; Winant, C; Yamashita, M;

Publicação
Proceedings of Science

Abstract
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~ 1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This method compromises the detector's ability to precisely determine the z coordinate of a particle interaction. However, we show for the first time that it is possible to discriminate bulk events from surface events based solely on the ionization signal. © Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence.

2008

Erratum to: "XENON" [Nucl. Phys. B (Proc. Suppl.) 173 (2007) 113-116] (DOI:10.1016/j.nuclphysbps.2007.08.142)

Autores
Aprile, E; Giboni, KL; Kamat, S; Monzani, ME; Plante, G; Yamashita, M; Gaitskell, RJ; Fiorucci, S; Sorensen, P; DeViveiros, L; Bernstein, A; Madden, N; Winant, C; Shutt, T; Kwong, J; Bolozdynya, A; Dahl, E; Oberlack, U; Shagin, P; Gomez, R; McKinsey, D; Manzur, A; Hasty, R; Ni, K; Arneodo, F; Ferella, A; Baudis, L; Angle, J; Orboeck, J; Manalaysay, A; Lopes, JAM; Coelho, L; Fernandes, L; Santos, J;

Publicação
Nuclear Physics B - Proceedings Supplements

Abstract

2008

Erratum to: "3D Position Sensitive XeTPC for Dark Matter Search" [Nucl. Phys. B (Proc. Suppl.) 173 (2007) 117-120] (DOI:10.1016/j.nuclphysbps.2007.08.033)

Autores
Angle, J; Aprile, E; Arneodo, F; Baudis, L; Bernstein, A; Bolozdynya, A; Coelho, L; Dahl, E; DeViveiros, L; Ferella, A; Fernandes, L; Fiorucci, S; Gaitskell, RJ; Giboni, KL; Gomez, R; Hasty, R; Kamat, S; Kwong, J; Lopes, JAM; Madden, N; Manalaysay, A; Manzur, A; McKinsey, D; Monzani, ME; Ni, K; Oberlack, U; Orboeck, J; Plante, G; Santos, J; Shagin, P; Shutt, T; Sorensen, P; Winant, C; Yamashita, M;

Publicação
Nuclear Physics B - Proceedings Supplements

Abstract

2007

XENON

Autores
Aprile, E; Giboni, K; Monzani, M; Plante, G; Yamashita, M; Gaitskell, R; Fiorucci, S; Sorensen, P; DeViveiros, L; Bernstein, A; Madden, N; Winant, C; Shutt, T; Kwong, J; Bolozdynya, A; Dahl, E; Oberlack, U; Shagin, P; Gomez, R; McKinsey, D; Manzur, A; Hasty, R; Ni, K; Arneodo, F; Ferella, A; Baudis, L; Angle, J; Orboeck, J; Manalaysay, A; Lopes, J; Coelho, L; Fernandes, L; Santos, J;

Publicação
Nuclear Physics B - Proceedings Supplements

Abstract

2007

Secondary scintillation yield in pure xenon

Autores
Montelro, CMB; Fernandas, LMP; Lopes, JAM; Coelho, LCC; Veloso, JFCA; Dos Santos, JMF; Glbonr, K; Aprlle, E;

Publicação
Journal of Instrumentation

Abstract
The xenon secondary scintillation yield was studied as a function of the electric field in the scintillation region, in a gas proportional scintillation counter operated at room temperature. A large area avalanche photodiode was used for the readout of the VUV secondary scintillation produced in the gas, together with the 5.9 keV x-rays directly absorbed in the photodiode. The latter was used as a reference for the determination of the number of charge carriers produced by the scintillation pulse and, thus, the number of VUV photons impinging the photodiode. A value of 140 photons/kV was obtained for the scintillation amplification parameter. The attained results are in good agreement with those predicted, for room temperature, by Monte Carlo simulation and Boltzmann calculations, as well as with those obtained for saturated xenon vapour, at cryogenic temperatures, and are about a factor of two higher than former results measured at room temperature. © 2007 IOP Publishing Ltd and SISSA.

2011

Design and performance of the XENON10 dark matter experiment

Autores
Aprile, E; Angle, J; Arneodo, F; Baudis, L; Bernstein, A; Bolozdynya, A; Brusov, P; Coelho, LCC; Dahl, CE; DeViveiros, L; Ferella, AD; Fernandes, LMP; Fiorucci, S; Gaitskell, RJ; Giboni, KL; Gomez, R; Hasty, R; Kastens, L; Kwong, J; Lopes, JAM; Madden, N; Manalaysay, A; Manzur, A; McKinsey, DN; Monzani, ME; Ni, K; Oberlack, U; Orboeck, J; Orlandi, D; Plante, G; Santorelli, R; dos Santos, JMF; Shagin, P; Shutt, T; Sorensen, P; Schulte, S; Tatananni, E; Winant, C; Yamashita, M;

Publicação
ASTROPARTICLE PHYSICS

Abstract
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso Underground Laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been published elsewhere. In this paper, we summarize the design and performance of the detector and its subsystems, based on calibration data using sources of gamma-rays and neutrons as well as background and Monte Carlo simulation data. The results on the detector's energy threshold, position resolution, and overall efficiency show a performance that exceeds design specifications, in view of the very low energy threshold achieved (< 10 keVr) and low background rate achieved.

  • 19
  • 26