Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

Publicações por Pedro Jorge

2011

Interferometric optical fiber inclinometer with dynamic FBG based interrogation

Autores
da Silveira, CR; Carvalho, JP; Jorge, PAS; Costa, JWA; Giraldi, MTR; Santos, JL; Carvalho Junior, EL; Figueredo, DO; Frazao, O;

Publicação
INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS

Abstract
The development of an interferometric optical fiber inclinometer is described in this paper. A weak tapered region is induced in a standard single mode fiber in the vicinity of the cleaved fiber tip, using a standard fusion splicer. In this situation an in-fiber Michelson interferometer is constructed that is sensitive to curvature applied in the tapered region. It is shown that depending on the angular range, fringe visibility and/or peak position depend strongly on the applied curvature enabling low cost dielectric inclinometer to be setup that is suitable for high voltage applications. It is presented an analysis of the sensor response by means of experimental measurements and manipulation of these experimental data through computational simulations. The results coming from the numerical simulations indicate a good performance of the sensor within range of angular variation between 3 and 6 degrees and 10 and 14 degrees. A low cost strategy to interrogate the response of sensor using electrically modulated fiber Bragg gratings, a photodetector and frequency analysis is described. The results presented by this electric interrogation technique show a good sensitivity in the range 3.5 to 5.5 degrees.

2008

Modal LPG-based Mach-Zehnder interferometer with controlled sensitivity for refractive index measurement

Autores
Caldas, P; Jorge, PAS; Araujo, F; Ferreira, LA; Rego, G; Santos, JL;

Publicação
19TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, PTS 1 AND 2

Abstract
In this work, an LPG-based Mach-Zehnder interferometer was evaluated as a sensing structure for environmental refractive index measurement. To interrogate this sensing device, coherence addressing and pseudo-heterodyne processing were used. The impact of stretching, bending and twisting the interferometer on the sensitivity to refractive index changes r was studied. It is shown that, due to the antisymmetric nature of cladding modes in arc-induced LPGs, it is possible to tune the system sensitivity by simple mechanical action.

2007

Simultaneous determination of oxygen and temperature using quantum dots and a ruthenium complex - art. no. 66191Y

Autores
Jorge, PAS; Silva, AJ; Benrashid, R; Santos, JL; Farahi, F;

Publicação
Third European Workshop on Optical Fibre Sensors

Abstract
An all-optical scheme for simultaneous determination of oxygen and temperature is presented. A ruthenium complex immobilized in a non-hydrolytic sol-gel matrix is used as oxygen sensor. Temperature information is provided by CdSe quantum dots immobilized in the same material. While the dye luminescence is quenched by oxygen and temperature, the nanocrystals luminescence depends only on temperature. Results presented demonstrate that the combined luminescence response allows to simultaneously assess both parameters using a single optical fiber system.

2011

Fabry-Perot cavities based on chemical etching for high temperature and strain sensing

Autores
Tafulo, PAR; Jorge, PAS; Santos, JL; Frazao, O;

Publicação
INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS

Abstract
In this paper, two novel hybrid multimode/single mode fiber Fabry-Perot (FP) cavities were compared. The cavities fabricated by chemical etching are presented as high temperature and strain sensors. In order to produce this FP cavity a single mode fiber was spliced to a graded index multimode fiber with 62.5 mu m core diameter. The multimode fiber was cut approximately 150 mu m away from the splice. Then the tip of the fiber containing the multimode fiber segment was dipped into a solution of 48% of HF during 8 minutes, creating a concavity due to the fact that the reaction between HF and the germanium doped fiber core is much faster than the reaction between HF and the pure silica cladding. By this method a concavity of approximately 100 mu m deep was created at the fiber tip. Two different FP cavities can be fabricated. The first cavity is obtained when a spliced with an identical tip concavity fiber (Sensor A) and the second is created when a tip concavity is spliced to a single mode fiber (Sensor B). The Fabry-Perot cavities were tested as a high temperature sensor in the range between room temperature and 800 degrees C and as strain sensors. A reversible shift of the interferometric peaks with temperature allowed to estimate a sensitivity of 0.75 +/- 0.03 pm/degrees C and 0.98 +/- 0.04 pm/degrees C for the sensor A and B respectively. For strain measurement sensor A demonstrated a sensitivity of 1.85 +/- 0.07 pm/mu epsilon and sensor B showed a sensitivity of 3.14 +/- 0.05 pm/mu epsilon. The sensors demonstrated the feasibility of low cost fiber optic sensors for high temperature and strain.

2009

Effect of fiber tapering in LPG-based Mach-Zehnder modal interferometers for refractive-index sensing

Autores
Caldas, P; Jorge, PAS; Araujo, F; Ferreira, LA; Rego, G; Santos, JL;

Publicação
Proceedings of SPIE - The International Society for Optical Engineering

Abstract
In this work, an LPG-based Mach-Zehnder modal interferometer with a tapered fiber section between the two LPGs is studied as a sensing structure for measuring environmental refractive index. To interrogate this sensing device, coherence addressing and pseudo-heterodyne processing were used. A fiber taper was made between the two LPGs to improve and tailor the sensitivity of the sensor. Experimental results show that the sensitivity to external refractive index increases with the length of the taper and that the sensitivity enhancement is stronger for lower order cladding modes. © 2009 SPIE.

2009

Fibre Bragg gratings as interrogation elements for surface plasmon resonance sensors

Autores
Diaz Herrera, N; Viegas, D; Jorge, PAS; Navarrete, MC; Ferreira, LA; Araujo, FM; Santos, JL; Gonzalez Cano, A;

Publicação
Proceedings of SPIE - The International Society for Optical Engineering

Abstract
A new interrogation method based on Fibre Bragg Gratings (FBG) for Surface Plamon Resonance (SPR) sensors in the region of refractive indices of aqueous solutions is described. Two FBGs are selected with their Bragg wavelengths at opposite sides of the plasmon resonance peak. The response of the system can be made independent of the fluctuations of the optical power source, and the linearity and the sensitivity of the sensor are improved. The use of the spectral selectivity of gratings for the interrogation of SPR sensors in different configurations is also promising in terms of multiplexing, temperature referencing or multiparameter detection. © 2009 SPIE.

  • 43
  • 45