Publicações por Orlando Frazão

2014

Cavity Ring-Down with OTDR for remote sensing

Autores
Passos, DJ; Silva, SO; Marques, MB; Frazao, O;

Publicação
23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS

Abstract
This work presents a demonstration of the potential of fiber cavity ring-down for remote sensing, by using an OTDR to send impulses down similar to 20 km of optical fiber at the end of which the fiber ring cavity was placed. The OTDR showed almost no losses in the fiber, so other ring-down cavities could be spliced along the same fiber. To study the sensitivity of the cavity ring an intensity sensor based on a taper was placed in the ring and glued to a translation stage. A displacement of the stage imposes a curvature on the taper and an associated loss. The configuration had a sensitivity of (11.8 +/- 0.5) mu s/mm.

2014

Characterization of a hybrid Fabry-Perot Cavity based on a four-bridge double-Y-shape-core microstructured fiber

Autores
Pinto, AMR; Lopez Aldaba, A; Lopez Amo, M; Frazao, O; Santos, JL; Baptista, JM; Baierl, H; Auguste, JL; Jamier, R; Roy, P;

Publicação
Proceedings of SPIE - The International Society for Optical Engineering

Abstract
In this work, a hybrid Fabry-Perot interferometer based on a novel four-bridge microstructured fiber is presented and characterized. The characterization of this cavity is performed in the L-band using two different instruments: an optical spectrum analyzer and an optical backscatter reflectometer. The Fabry-Perot output signal presents linear variation with temperature changes (sensitivity 9.8-11.9 pm/°C), variation with the polarization states of light and high stability. © 2014 SPIE.

2013

Chemical sensing by differential thermal analysis with a digitally controlled fiber optic interferometer

Autores
Goncalves, LC; Gonzalez Aguilar, G; Frazao, O; Baptista, JM; Jorge, PAS;

Publicação
REVIEW OF SCIENTIFIC INSTRUMENTS

Abstract
In this work the implementation of an optical fiber interferometric system for differential thermal analysis enabling the identification of chemical species is described. The system is based on a white light Mach-Zehnder configuration using pseudo-heterodyne demodulation to interrogate two identical fiber Bragg gratings (FBG) in a differential scheme. System performance is compared using either standard hardware or low cost virtual instrumentation for operation control and signal processing. The operation with the virtual system enabled temperature measurements with a +/-0.023 degrees C resolution nearly matching the performance of the standard hardware. The system ability to discriminate chemical species by differential thermal analysis was demonstrated. Mixed samples of acetone and methanol could be successfully identified, indicating the suitability of the system for high precision measurements using low cost instrumentation. (C) 2013 American Institute of Physics. [http://dx.doi.org/10.1063/1.4774054]

2017

Combined Microfiber Knot Resonator and Focused Ion Beam-Milled Mach-Zehnder Interferometer for Refractive Index Measurement

Autores
Gomes, AD; Andre, RM; Warren Smith, SC; Dellith, J; Becker, M; Rothhardt, M; Frazao, O;

Publicação
2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS)

Abstract
A Mach-Zehnder interferometer was created from a cavity milled in the taper region next to a microfiber knot resonator. A focused ion beam was used to mill the cavity with 47.8 mu m in length. The microfiber knot resonator was created from an 11 mu m diameter taper, produced using a filament fusion splicer. After milling the cavity, the microfiber knot resonator spectrum is still visible. The final response of the presented sensor is a microfiber knot resonator spectrum modulated by the Mach-Zehnder interference spectrum. A preliminary result of -8935 +/- 108 nm/RIU was obtained for the refractive index sensitivity of the cavity component in a refractive index range of n = 1.333 to 1.341. Simultaneous measurement of refractive index and temperature using this combined structure is a future goal.

2014

Control of the strain sensitivity using a suspended core photonic crystal fiber sensing head

Autores
Rota Rodrigo, S; Lopez Amo, M; Kobelke, J; Schuster, K; Santos, JL; Frazao, O;

Publicação
23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS

Abstract
In this work a strain sensor based on a suspended core fiber is proposed. The sensor comprises a suspended core PCF between SMFs and is based on the multimode interference generated in these transitions. A strain sensitivity study for different sensing heads and stage separation lengths was carried out showing a sensitivity of -2.42 pm/mu epsilon for the best case. Also the sensing head was tested for curvature and temperature, showing in the first case that it is insensitive to curvature effects, and secondly, that for small sensor lengths it was insensitive to temperature variations.

2014

A FABRY-PEROT SENSOR PROTOTYPE FOR LOW-PRESSURE MEASUREMENTS

Autores
Roriz, P; Ferreira, MS; Schuster, K; Kobelke, J; Frazaeo, O;

Publicação
MICROWAVE AND OPTICAL TECHNOLOGY LETTERS

Abstract
An interferometric Fabry-Perot cavity based on hollow-core ring photonic crystal fiber combined with a silicone diaphragm is proposed for low pressure sensing. The sensor exhibits a sensitivity of 0.086 nm/mmHg for a pressure range between 0 and 337.5 mmHg. These values are in the range of physiological pressures, such as intravascular pressure. (C) 2014 Wiley Periodicals, Inc.

  • 5