2022
Autores
Perez-Herrera, RA; Soares, L; Silva, S; Frazao, O;
Publicação
SENSORS
Abstract
In this study, an interrogation system based on an erbium-doped fiber ring cavity for refractive index measurements is presented and experimentally demonstrated. This cavity ring includes a 1 x 3 coupler wherein one of the fiber output ports is used to increase the optical power of the system by means of an FBG used as a reflector. The other two output ports are used as a refractive index sensing head and reference port, respectively. An experimental demonstration of this proposed sensor system for the measurement of a distinct refractive index is presented.
2022
Autores
Rodrigues, AV; Reis, J; Martins, AJM; Monteiro, CS; Silva, SO; Caridade, CMR; Tavares, SO; Frazao, O;
Publicação
MICROWAVE AND OPTICAL TECHNOLOGY LETTERS
Abstract
This study presents the dependence of strain sensitivity on cavity length in conventional Fabry-Perot (F-P) sensors. A high number of F-P sensors were required and to ensure their reproducibility, a manufacturing process was developed to obtain similar sensors but with different types of lengths. A hollow-core silica tube was used to fabricate several F-P cavities by fusion splicing it between two sections of SMF28 fiber. The fabricated F-P has a varying length ranging from 15 to 2500 mu m. The cavities were measured under a microscope and the reflected spectrum was acquired for each one. Strain measurements were performed for a maximum strain of 1000 mu epsilon. The strain sensitivity showed a highly linear correlation with increment lambda(FSR). Small length variations for short cavities heavily affect the FSR value. The smallest and longest cavities present sensitivities of 8.71 and 2.68 pm/mu epsilon, respectively. Thermal characterization for low- and high-temperature regimes was also performed and is constant for tested sensors.
2023
Autores
Soares, L; Perez Herrera, RA; Novais, S; Ferreira, A; Silva, S; Frazao, O;
Publicação
PHOTONICS
Abstract
Process Analytical Technology (PAT) has been increasingly used in the pharmaceutical industry to monitor essential parameters in real-time during pharmaceutical processes. The concentration of Active Pharmaceutical Ingredients (APIs), such as paracetamol, is one of these parameters, and controlling its variations allows for optimization of the production process. In this study, a refractometric sensor, implemented by an interrogation system based on an Erbium-Doped Fiber Ring Cavity (EDFRC), was presented and experimentally demonstrated. The Cavity Ring proposed included a 1 x 3 coupler. One port of the coupler was used to increase the optical power of the system through a Fiber Bragg Grating (FBG), and the other two ports were used as sensing head and reference. The sensor detected variations of paracetamol concentration with a sensitivity of [(-1.00 +/- 0.05) x 10(-3)] nW/(g/kg) and a resolution of 5.53 g/kg. The results demonstrate the potential of this technology as a possible non-invasive PAT tool.
2023
Autores
Robalinho, P; Soares, B; Lobo, A; Silva, S; Frazao, O;
Publicação
SENSORS
Abstract
In this paper, a different Fiber Loop Mirror (FLM) configuration with two circulators is presented. This configuration is demonstrated and characterized for sensing applications. This new design concept was used for strain and torsion discrimination. For strain measurement, the interference fringe displacement has a sensitivity of (0.576 +/- 0.009) pm.mu epsilon(-1). When the FFT (Fast Fourier Transformer) is calculated and the frequency shift and signal amplitude are monitored, the sensitivities are (-2.1 +/- 0.3) x 10(-4) nm(-1) mu epsilon(-1) and (4.9 +/- 0.3) x 10(-7) mu epsilon(-1), respectively. For the characterization in torsion, an FFT peaks variation of (-2.177 +/- 0.002) x 10(-12) nm(-1)/degrees and an amplitude variation of (1.02 +/- 0.06) x 10(-3)/degrees are achieved. This configuration allows the use of a wide range of fiber lengths and with different refractive indices for controlling the free spectral range (FSR) and achieving refractive index differences, i.e., birefringence, higher than 10(-2), which is essential for the development of high sensitivity physical parameter sensors, such as operating on the Vernier effect. Furthermore, this FLM configuration allows the system to be balanced, which is not possible with traditional FLMs.
2023
Autores
Perez Herrera, RA; Soares, L; Novais, S; Frazão, O; Silva, S;
Publicação
Proceedings of SPIE - The International Society for Optical Engineering
Abstract
2023
Autores
Soares, L; Perez-Herrera, RA; Novais, S; Ferreira, A; Frazao, O; Silva, S;
Publicação
2023 IEEE 7TH PORTUGUESE MEETING ON BIOENGINEERING, ENBENG
Abstract
A linear fiber laser system for measurements of paracetamol concentration is experimentally demonstrated. The cavity is based on a fiber loop mirror and an FBG centered at 1567.8 nm. The sensing head corresponds to a refractometric sensor, whose which principle of operation is based on Fresnel reflection in the fiber tip (FBG side). The system works at detected variations of paracetamol concentrations with a sensitivity of [(8.74 +/- 0.34) x10(-5)] mu W/(g/kg) and a resolution of 2.77 g/kg. The results prove that the fiber laser system could be an asset for processing industries, specifically for non-invasive and real-time measurements of concentration.
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.