Publicações por Susana Oliveira Silva

2017

Strain sensor based on hollow microsphere Fabry-Perot cavity

Autores
Monteiro, CS; Silva, SO; Frazao, O;

Publicação
THIRD INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS

Abstract
Fusion splicing technique was explored for the fabrication of two sensing structures based on hollow microsphere Fabry-Perot cavity. The first sensor proposed was fabricated with a hollow microsphere tip, working as a probe sensor. This structure was studied for lateral load pressure, yielding a 1.56 +/- 0.01 nm/N sensitivity. The second sensing structure relied on an in-line hollow microsphere, which allowed the detection of lateral load, with a sensitivity of 2.62 +/- 0.02 nm/N. Furthermore, the proposed structure enabled strain sensing, with a sensitivity of 4.66 +/- 0.03 pm/mu epsilon. The two sensing structures were subjected to temperature, presenting low thermal cross-sensitivity.

2014

Multiparameter measurement using a double-Y-shaped suspendedcore fiber in a fiber loop configuration

Autores
Silva, SF; Baierl, H; Auguste, JL; Jamier, R; Roy, P; Baptista, JM; Santos, JL; Frazao, O;

Publicação
23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS

Abstract
In this work, an all-fiber loop mirror using a four-bridge silica fiber with a double-Y-shaped suspended-core is presented for the measurement of strain and torsion. The sensing head is formed by a section of the microstructured fiber with 90 mm in length. The fiber loop sensor allowed observing a distinct interference pattern as a result of the geometry of the core fiber. Different sensitivities to strain and torsion were obtained, namely, -5.11 pm/mu e and +/- 1.34 pm/degree.

2016

CAVITY RING-DOWN TECHNIQUE FOR REMOTE SENSING

Autores
Silva, S; Marques, MB; Frazao, O;

Publicação
MICROWAVE AND OPTICAL TECHNOLOGY LETTERS

Abstract
This work demonstrates the viability of using a cavity ring-down (CRD) technique for remote sensing. A conventional CRD configuration is used where an optical circulator is added inside the fiber loop to couple 19 km of optical fiber with a gold mirror at its end with the purpose of remote sensing. As a proof-of-concept, an intensity sensor based on an eight-figure configuration is used at the end of the 19 km of fiber for displacement sensing. (C) 2016 Wiley Periodicals, Inc.

2017

Analysis of Signal Saturation in a Fiber Ring Resonator integrating an Intensity Sensor

Autores
Magalhaes, R; Silva, SO; Frazao, O;

Publicação
2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS)

Abstract
The proposed technique consists in an optical fiber resonator interrogated for sensor characterization, implementing an alternative technique for dynamic range improvement. Such technique relies on the analysis of an added-signal caused by signal saturation, which occurs due to the broadening of the laser pulse. A wide study for different pulse widths is presented in this work, namely for 100 ns, 5 mu s and 20 mu s, being the last one related to the emergence of an added-signal for the proposed configuration. The behavior of the waveform in the presence of an intensity sensor is also characterized.

2017

Fiber Bragg grating sensor based on cantilever structure embedded in polymer 3D printed material

Autores
Lima, R; Tavares, R; Silva, SO; Abreu, P; Restivo, MT; Frazao, O;

Publicação
2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS)

Abstract
A cantilever structure in 3D printed based on a fiber Bragg grating (FBG) sensor embedded in polymer material is proposed. The FBG sensor was embedded in 3D printed coating and was tested under three physical parameters: displacement, temperature and vibration. The sensor was tested in displacement in two different regions of the cantilever, namely, on its midpoint and end point. The maximum displacement sensitivity achieved was (3 +/- 0.1) pm/mm for end point displacement, and a temperature sensitivity of (30 +/- 1) pm/degrees C was also attained. In the case of vibration measurements it was possible to obtain a 10.23Hz-low frequency oscillation.

2017

Recent Advances in Fiber Cavity Ring-down Technology

Autores
Silva, S; Frazao, O;

Publicação
PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PHOTONICS, OPTICS AND LASER TECHNOLOGY (PHOTOPTICS)

Abstract
A brief review in the fibre cavity ring-down (CRD) technique is presented. It addresses the latest developments in CRD technique for sensing applications, undergone at INESC TEC. The CRD is based on the conventional configuration with the possibility of adding amplification in order to compensate the output signal losses induced by the sensing head. The results obtained for strain, curvature and refractive index sensing are presented, corresponding to distinct sensing structures, namely, a chirped fibre Bragg grating (FBG), a long period grating (LPG) and a multimode interference (MMI) based sensor.