Cookies
O website necessita de alguns cookies e outros recursos semelhantes para funcionar. Caso o permita, o INESC TEC irá utilizar cookies para recolher dados sobre as suas visitas, contribuindo, assim, para estatísticas agregadas que permitem melhorar o nosso serviço. Ver mais
Aceitar Rejeitar
  • Menu
Publicações

Publicações por Catarina Silva Monteiro

2017

Embedded Fabry-Perot based Sensor Using Three-Dimensional Printing Technology

Autores
Monteiro, CS; Santos, BF; Silva, SO; Abreu, P; Restivo, MT; Frazao, O;

Publicação
2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS)

Abstract
A sensor based on Fabry-Perot interferometry with a hollow microsphere cavity embedded in a 3D printed structure is proposed. The sensor was tested for lateral loading and temperature, showing promising results. By imprintring the sensor on the structure, the dynamic range of application is severely increased enabling the application of the sensor in harsh environments.

2017

Fabry-Perot Sensor based on Two Coupled Microspheres for Strain Measurement

Autores
Monteiro, CS; Kobelke, J; Schuster, K; Bierlich, J; Frazao, O;

Publicação
2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS)

Abstract
A Fabry-Perot based sensor with two coupled hollow microspheres is presented. The sensor was fabricated using fusion splicing techniques, enabling a low-cost, highly reproducible, production. The coupling of the two microspheres gives rise to a highly sensitive strain sensor, reaching a sensitivity of 4.07 pm/mu epsilon. The allsilica composition leads to a low thermal sensitivity, making the proposed structure suitable applications in environments with varying external conditions.

2017

Strain sensor based on hollow microsphere Fabry-Perot cavity

Autores
Monteiro, CS; Silva, SO; Frazao, O;

Publicação
THIRD INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS

Abstract
Fusion splicing technique was explored for the fabrication of two sensing structures based on hollow microsphere Fabry-Perot cavity. The first sensor proposed was fabricated with a hollow microsphere tip, working as a probe sensor. This structure was studied for lateral load pressure, yielding a 1.56 +/- 0.01 nm/N sensitivity. The second sensing structure relied on an in-line hollow microsphere, which allowed the detection of lateral load, with a sensitivity of 2.62 +/- 0.02 nm/N. Furthermore, the proposed structure enabled strain sensing, with a sensitivity of 4.66 +/- 0.03 pm/mu epsilon. The two sensing structures were subjected to temperature, presenting low thermal cross-sensitivity.

2016

Curvature Sensor Based on a Fabry-Perot Interferometer

Autores
Monteiro, CS; Ferreira, MS; Kobelke, J; Schuster, K; Bierlich, J; Frazao, O;

Publicação
SIXTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS

Abstract
A curvature sensor based on a Fabry-Perot interferometer is proposed. A capillary tube of silica is fusion spliced between two single mode fibers, producing a Fabry-Perot cavity. The light propagates in air, when passing through the capillary tube. Two different cavities are subjected to curvature and temperature. The cavity with shorter length shows insensitivity to both measurands. The larger cavity shows two operating regions for curvature measurement, where a linear response is shown, with a maximum sensitivity of 18.77pm/m(-1) for the high curvature radius range. When subjected to temperature, the sensing head produces a similar response for different curvature radius, with a sensitivity of 0.87pm/degrees C.

2016

Fiber Fabry-Perot Interferometer for Curvature Sensing

Autores
Monteiro, CS; Ferreira, MS; Silva, SO; Kobelke, J; Schuster, K; Bierlich, J; Frazao, O;

Publicação
PHOTONIC SENSORS

Abstract
A curvature sensor based on an Fabry-Perot (FP) interferometer was proposed. A capillary silica tube was fusion spliced between two single mode fibers, producing an FP cavity. Two FP sensors with different cavity lengths were developed and subjected to curvature and temperature. The FP sensor with longer cavity showed three distinct operating regions for the curvature measurement. Namely, a linear response was shown for an intermediate curvature radius range, presenting a maximum sensitivity of 68.52 pm/m(-1). When subjected to temperature, the sensing head produced a similar response for different curvature radii, with a sensitivity varying from 0.84 pm/degrees C to 0.89 pm/degrees C, which resulted in a small cross-sensitivity to temperature when the FP sensor was subjected to curvature. The FP cavity with shorter length presented low sensitivity to curvature.

2017

Hollow Microsphere Fabry-Perot Cavity for Sensing Applications

Autores
Monteiro, C; Silva, S; Frazao, O;

Publicação
IEEE PHOTONICS TECHNOLOGY LETTERS

Abstract
Two different sensing structures based on a hollow microsphere Fabry-Perot cavity are proposed. The hollow spheroidal cavities are fabricated resorting only to fusion splicing. The first structure is based on a hollow microsphere located at the fiber end and works as a probe sensor. The structure was subjected to lateral load pressure and presents a sensitivity of 1.56 +/- 0.01 nm/N. The second proposed sensor relies on an in-line hollow microsphere. The sensing structure allows the detection of lateral loading, with a sensitivity of 2.62 +/- 0.02 nm/N, as well as strain detection, with a sensitivity of 4.66 +/- 0.03 pm/mu epsilon. The two proposed sensors present similar response when subjected to temperature and have low thermal sensitivity.

  • 1
  • 6