2014
Autores
Ferreira, MS; Lee, GCB; Santos, JL; Sugden, K; Frazão, O;
Publicação
Optical Sensors, 2014
Abstract
In this work, a phase-shifted fiber Bragg grating is proposed for strain sensing at extreme temperatures. The grating structure is written in bare standard single mode fiber, using the point-by-point femtosecond laser technique. Strain measurements are performed at temperatures ranging from room temperature up to 900°C. By subjecting the sensor to such extreme conditions, the wavelength of the grating increases. © 2014 OSA.
2017
Autores
Ferreira, MS; Bierlich, J; Kobelke, J; Santos, JL; Frazao, O;
Publicação
THIRD INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS
Abstract
A Fabry-Perot interferometer based on an array of soda-lime glass microspheres is proposed for temperature sensing. The microspheres are introduced in a hollow-core silica tube using a tapered fiber tip. After the insertion of each microsphere the sensor is subjected to temperature measurements. The sensor exhibits non-linear behavior and a dependence on the number of microspheres is observed. A maximum sensitivity of 11.13 pm/degrees C is achieved, when there is only one microsphere inside the capillary structure.
2016
Autores
Trindade, IG; da Silva, JM; Miguel, R; Pereira, M; Lucas, J; Oliveira, L; Valentim, B; Barreto, J; Silva, MS;
Publicação
SENSORS
Abstract
This article addresses the design, development, and evaluation of T-shirt prototypes that embed novel textile sensors for the capture of cardio and respiratory signals. The sensors are connected through textile interconnects to either an embedded custom-designed data acquisition and transmission unit or to snap fastener terminals for connection to external monitoring devices. The performance of the T-shirt prototype is evaluated in terms of signal-to-noise ratio amplitude and signal interference caused by baseline wander and motion artefacts, through laboratory tests with subjects in standing and walking conditions. Performance tests were also conducted in a hospital environment using a T-shirt prototype connected to a commercial three-channel Holter monitoring device. The textile sensors and interconnects were realized with the assistance of an industrial six-needle digital embroidery tool and their resistance to wear addressed with normalized tests of laundering and abrasion. The performance of these wearable systems is discussed, and pathways and methods for their optimization are highlighted.
2017
Autores
Coelho, L; de Almeida, JMMM; Santos, JL; Jorge, PAS;
Publicação
OCEANS 2017 - ABERDEEN
Abstract
Long period fibre gratings (LPFG) have found an increasing interest due to the easy fabrication in any kind of fibre through the induced electric arc technique with low cost and flexibility. They have been used in applications such as gain-flattening and band-rejection, and for sensing strain, temperature and chemical and biological parameters. The sensitivity of LPFG increases when the fibre is coated with certain thin films. In this short review it is presented the recent developments and applications of these kind of sensors.
2019
Autores
Lobo Ribeiro, ABL; Silva, SFO; Frazao, O; Santos, JL;
Publicação
MEASUREMENT SCIENCE AND TECHNOLOGY
Abstract
Bi-core optical fiber structures are studied for applications in sensing. In this paper, an analysis is performed on the spectral characteristics of light propagating in these fibers with central launching core illumination from a standard single mode fiber. Reflective and transmissive configurations are addressed. The characteristics of a reflective bi-core fiber structure for measurement of strain, temperature and absolute value of torsion are investigated and highlights for further research are presented.
2018
Autores
Silva, GE; Caldas, P; Santos, JL; Santos, JC;
Publicação
Optics InfoBase Conference Papers
Abstract
This paper presents preliminary results of common water thermal conductivity measurements using an all-fiber sensor based in conventional hot-wire method concept. The thermal conductivity of common water at room temperature obtained is 0.699 W/mK. Although the result is relatively distinct, about 14%, from the reference value found in literature, it is promising and indicates the feasibility of using the experimental arrangement for measuring thermal properties of materials with higher accuracy, provided that improvements already foreseen in future work be incorporated. © OSA 2018 © 2018 The Author(s)
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.