Publicações por Manuel Joaquim Marques

2008

TEMPERATURE SENSOR USING Hi-Bi ERBIUM-DOPED FIBER LOOP MIRROR

Autores
Frazao, O; Egypto, D; Bittencourt, LA; Giraldi, MTMR; Marques, MB;

Publicação
MICROWAVE AND OPTICAL TECHNOLOGY LETTERS

Abstract
In this letter, a temperature sensor using a fiber loop mirror containing a piece of highly birefringent erbium doped fiber is presented. A Hi-Bi PANDA erbium-doped silica fiber was used and compared with the conventional Hi-Bi PANDA fiber. Different results for strain and temperature sensitivity were obtained. The temperature coefficient sensitivity was -2.22 nm/degrees C and significantly higher when compared with others conventional Hi-Bi fibers. Strain experiments were also performed. (C) 2008 Wiley Periodicals, Inc. Microwave Opt Technol Lett 50: 3152-3154 2008; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.23907

2011

300 km-ultralong Raman fiber lasers using a distributed mirror for sensing applications

Autores
Martins, H; Marques, MB; Frazao, O;

Publicação
OPTICS EXPRESS

Abstract
Several configurations of ultralong Raman fiber lasers (URFL) based on a distributed mirror combined with Bragg gratings or fiber loop mirrors are studied. Two continuous-wave URFL configurations, with single and cascaded cavities using fiber Bragg gratings as mirrors are explored for a 300 km long fiber. For optical sensing, the cavity length was optimized for 250 km using one of the gratings an intensity sensor. Another URFL configuration based in a fiber loop mirror is also reported. For optical sensing using a 300 km long fiber it is shown that the best choice is a hybrid configuration. The sensitivity of the FBG laser sensor range was from (76 +/- 2) x 10(-6) mu epsilon(-1) (for lower strain) to (9.0 +/- 0.4) x 10 -6 mu epsilon(-1) (for higher strain). (C) 2011 Optical Society of America

2011

Comparison of Brillouin-Raman Comb Fiber Laser in Two Different Configurations

Autores
Martins, H; Marques, MB; Frazao, O;

Publicação
LASER PHYSICS

Abstract
The properties of a Brillouin-Raman comb fiber laser are compared for two different configurations: co-propagating and counter-propagating Raman pump. The optical spectrum is compared for changing the Raman pump power and the power or the wavelength of seed laser. A Brillouin-Raman comb with 400 linewidth lasers in a flat-amplitude bandwidth of 32 nm between 1538 and 1570 nm, with an average optical power 20 dB above the nearby frequencies was generated. The lasers in the comb had an OSNR of 20 dB and a wavelength spacing of 0.08 nm. The results for the counter-propagating configuration were observed to have better quality.

2010

Fiber Loop Mirror Using a Small Core Microstructured Fiber for Strain and Temperature Discrimination

Autores
Andre, RM; Marques, MB; Roy, P; Frazao, O;

Publicação
IEEE PHOTONICS TECHNOLOGY LETTERS

Abstract
In this work, a fiber loop mirror for the simultaneous measurement of strain and temperature is presented. The loop mirror contains a section of a small core microstructured fiber characterized for strain and temperature sensing. Due to the small core geometry and using a small section length, the structure presents high birefringence and also intermodal interference. The spectral response of this configuration shows the presence of three interferometers. One of them corresponds to the interference of light that propagates in the fast and slow axes (group birefringence) and the others are associated with the interference of light in the two lowest order spatial modes in each of the fiber eigenaxis. These interferometers present distinct sensitivities to strain and temperature for different wavelengths.

2008

Strain and temperature discrimination using high-birefringence erbium-doped fiber loop mirror with high pump power laser

Autores
Frazao, O; Egypto, D; Aragao Bittencourt, L; Giraldi, MTMR; Marques, MB;

Publicação
IEEE PHOTONICS TECHNOLOGY LETTERS

Abstract
This work presents a method to tune the sensitivity of the sensor in a highly birefringent erbium-doped fiber loop mirror (FLM) when it is pumped. This concept was used for simultaneous measurement of strain and temperature. The FLM is sequentially pumped and unpumped by a high pump laser at 980 nm to change the erbium-doped fiber properties. The sensing head changes its sensitivity when subjected to strain and/or temperature variations due to thermal effects originated by the pump laser.

2009

Low-Coherence Interferometry for Measuring Polarization Mode Dispersion

Autores
Amaral, LMN; Pereira, DA; Frazao, O; Marques, MB; Lima, MJN; Teixeira, ALJ;

Publicação
ICTON: 2009 11TH INTERNATIONAL CONFERENCE ON TRANSPARENT OPTICAL NETWORKS, VOLS 1 AND 2

Abstract
An interferometric setup for measuring Polarization Mode Dispersion (PMD) setup was tested. Using a low-coherence technique with a Michelson interferometer, it was possible to measure values of PMD from detected Differential Group Delay (DGD) values in two reels. The low-coherence source bounds the minimum value of DGD detected to 0.13 ps, leading to a minimum value detected around 0.14 ps. The mean value of PMD measured over a period of several days for one reel was 0.0405 +/- 0.0007 ps/km(1/2), and 0.0463 +/- 0.0044 ps/km(1/2) for the other. Stochastic and random behavior of PMD was observed.