2020
Autores
Miyandoab, FD; Ferreira, JC; Tavares, VMG; da Silva, JM; Velez, FJ;
Publicação
IEEE-ACM TRANSACTIONS ON NETWORKING
Abstract
A multifunctional router IC to be included in the nodes of a wearable body sensor network is described and evaluated. The router targets different application scenarios, especially those including tens of sensors, embedded into textile materials and with high data-rate communication demands. The router IC supports two different functionality sets, one for sensor nodes and another for the base node, both based on the same circuit module. The nodes are connected to each other by means of woven thick conductive yarns forming a mesh topology with the base node at the center. From the standpoint of the network, each sensor node is a four port router capable of handling packets from destination nodes to the base node, with sufficient redundant paths. The adopted hybrid circuit and packet switching scheme significantly improve network performance in terms of end-to-end delay, throughput and power consumption. The IC also implements a highly precise, sub-microsecond one-way time synchronization protocol which is used for time stamping the acquired data. The communication module was implemented in a 4-metal, 0.35 mu m CMOS technology. The maximum data rate of the system is 35 Mbps while supporting up to 250 sensors, which exceeds current BAN applications scenarios.
2020
Autores
da Silva, JM; Cerrone, I; Malagon, D; Marinho, J; Mundy, S; Gaspar, J; Mendes, JG;
Publicação
2020 23RD EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN (DSD 2020)
Abstract
The present work aims at developing a smart dental implant meant to restore the proprioceptive control of the masticatory muscle activity, in consequence of the loss of natural teeth. When periodontal afferent information is not available, the control of the occlusal forces is impaired and the capacity of regulating the masticatory force on a certain tooth or teeth is affected. The active implant being proposed detects the force exerted on teeth and proportionally generates stimuli to send that information to the brain in order to restore the neurobiological mechanisms associated to the masticatory sensory-motor function. After the description of the physiological and biomechanical aspects related to the loss of teeth and masticatory function, details are provided on the force sensing, processing and stimuli generation circuits included in the active implant being proposed. Preliminary simulation results that illustrate the implant functionality are presented.
2021
Autores
Martins, C; da Silva, JM; Guimaraes, D; Martins, L; da Silva, MV;
Publicação
REVISTA PORTUGUESA DE CARDIOLOGIA
Abstract
Heart failure (HF) is a multifactorial chronic syndrome with progressive increasing incidence causing a huge financial burden worldwide. Remote monitoring should, in theory, improve HF management, but given increasing morbidity and mortality, a question remains: are we monitoring it properly? Device-based home monitoring enables objective and continuous measurement of vital variables and non-invasive devices should be first choice for elderly patients. There is no shortage of literature on the subject, however, most studies were designed to monitor a single variable or class of variables that were not properly assembled and, to the best of our knowledge, there are no large randomized studies about their impact on HF patient management. To overcome this problem, we carefully selected the most critical possible HF decompensating factors to design MONITORIA, a non-invasive device for comprehensive HF home monitoring. MONITORIA stands for MOnitoring Non-Invasively To Overcome mortality Rates of heart Insufficiency on Ambulatory, and in this paper, which is part I of a series of three articles, we discuss the theoretical basis for its design. MONITORIA and its inherent follow-up strategy will optimize HF patient care as it is a promising device, which will essentially adapt innovation not to the disease but rather to the patients. (C) 2020 Sociedade Portuguesa de Cardiologia. Published by Elsevier Espana, S.L.U.
2021
Autores
Martins, C; da Silva, JM; Guimaraes, D; Martins, L; Da Silva, MV;
Publicação
REVISTA PORTUGUESA DE CARDIOLOGIA
Abstract
Introduction: Heart failure (HF) represents a huge financial and economic burden worldwide. Some authors advocate that remote monitoring should be implemented to improve HF management, but given its increasing incidence, as well as its morbidity and mortality, a question still remains: are we monitoring it properly? There is no shortage of literature on home monitoring devices, however, most of them are designed to monitor an unsuitable array of variables and, to the best of our knowledge, there are no large randomized studies about their impact on morbidity/mortality of HF patients. Objective: Description of a novel monitoring device. Methods: As a solution, we designed MONITORIA (MOnitoring NonInvasively To Overcome mortality Rates of heart Insufficiency on Ambulatory). Results: This is a multimodal device that will provide real time monitoring of vital, electrophysiological, hemodynamic and chemical signs, transthoracic impedance, and physical activity levels. The device is meant to perform continuous analysis and transmission of all data. Significant alterations in a patient's variable will alert the attending physician and, in case of potentially life-threatening situations, the national emergency medical system. The MONITORIA device will, also, have a function that sends shocks or functions as a pacemaker to treat certain arrhythmias/blockades. This function can be activated the very first time the patient utilizes it, based on their risk of sudden cardiac death. Discussion/Conclusions: MONITORIA is a promising device mostly because it is included in a follow-up program that takes into account a multi-perspective feature of HF development and is based on the real world patient, adapting innovations not to the disease but rather to the patients. (C) 2021 Sociedade Portuguesa de Cardiologia. Published by Elsevier Espana, S.L.U.
2020
Autores
da Silva, JM; Cerrone, I; Malagon, D; Marinho, J; Mundy, S; Gaspar, J; Mendes, JG;
Publicação
2020 XXXV CONFERENCE ON DESIGN OF CIRCUITS AND INTEGRATED SYSTEMS (DCIS)
Abstract
Natural teeth eventually fall out as one becomes older, making it more difficult chewing, speaking and get a reference plane for the body postural equilibrium. To minimize the problem, the missing teeth are eventually replaced by implants that restore the referred functions but miss the sensing of the applied force. As a consequence, the masticatory forces become erratic as the brain receives no feedback (or inaccurate) sensing information. The present work aims at developing a preliminary prototype of a smart dental implant meant to restore the proprioceptive control of the masticatory and chewing muscle activity. After the description of the physiological and biomechanical aspects related to tooth loss, details are provided on the force sensing and electrical stimulation provided by the active implant being proposed. Simulation results obtained with the development tool of the GreenPAK programmable chip being used are included.
2007
Autores
Hamdioui, S; Orailoglu, A; Van Der Meijs, N; Da Silva, JM;
Publicação
Proceedings - 2007 International Conference on Design and Technology of Integrated Systems in Nanoscale Era, DTIS 2007
Abstract
The access to the final selection minute is only available to applicants.
Please check the confirmation e-mail of your application to obtain the access code.